PTC-06204 Series0 pages
PTC-06204 SERIES
DC/DC CONVERTERS
MINIATURE, HIGH DENSITY, HIGH EFFICIENCY
SINGLE OUTPUT
(UP TO 500W)
Applications
Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial
Special Features
• Miniature size
• High efficiency
• Wide input range
• Input / Output isolation
• Remote sense
• External On/Off Inhibit
• Zero Voltage Switching Technology
• Fixed switching frequency (250 KHz)
• External synchronization capability
• EMI/RFI filters included
• Inrush circuit.
• Indefinite short circuit protection with
auto-recovery
• Over-voltage shutdown with
auto-recovery
• Over temperature shutdown with
auto-recovery
DC Input:
DC Input range: 220-350VDC
DC Output:
Output range – 1.8V to 28V
Output power – 350W (peak 500W)
Output current – max. 50A
Isolation
500V between Input and Output
500V between Input and Case
100V between Output and Case
Line/Load regulation:
Less than 1%
(no load to full load, –55°C to +85°C)
Efficiency :
Typical 88-90%
(full load, room temperature)
EMI/RFI:
Design to meet or exceed
MIL-STD-461C:CE03, CE07, CS01, CS02,
CS06, RE02, RS02, RS03
Ripple and Noise:
Less than 50mVp-p, typical (max. 1%)
without external capacitance.
When connected to system capacitance
ripple drops significantly
Load Transient Overshoot and
Undershoot
Output resistance at load change of 50%100% is 30-200mOhm (depending on output
voltage). Output back to steady stated within
300-500µSec
Turn on Transient
Voltage overshoot at during power on is
less than 1% nominal voltage
Output
• Electronic over voltage protection –
Internal control protects unit (no damage)
10% above nominal voltage
• Passive tranzorb on outputs –
20% above nominal voltage
• Current limiting – Continuous protection
(10-30% above maximum current) for
unlimited time (Hiccup)
General
• Over temperature protection:
Shutdown at base plate temperature of
+105°C (±5°C) Automatic recovery at
base plate temperature lower than
+95°C (±5°C)
Electrical Specifications
Protections*
Input
• Inrush circuit Protection
• Inrush Current Limiter –
peak value of 5 x Iin for less than 50µSec
• Under voltage protection –
unit protects itself (no damage) below
200Vdc
• Over voltage protection –
unit protects itself (no damage) above
380Vdc
* Thresholds and protections can be modified / removed – please consult factory.
PTC
Production & Trading Company AG
Gewerbestrasse 9, P.O. Box, CH-6330 Cham, Switzerland
phone 041 740 4554, fax 041 740 4664, http://www.ptcag.ch, e-mail: ptc@bluewin.ch
FILE: PTC-06204, Page 1 of 4
Rev -:2012-02-21