Xg Series0 pages
Rack Mount type v^vMatsusada Prcision X-ray HV Power Supply Anode ground type XPg Series 1057-06A-1 ■ FEATURES Maximum 3kW and 4kW output power models are also available. 镕 For Anode ground type X-ray tube Integrated Floating AC Filament Supply Օ Low ripple and high stability Digital interface Օ Constant Voltage/Current operation with full protection for safety operation ■ SUMMARY XPg Series is high stability and low ripple negative X-ray power supply with floating AC filament supply and generates staͭble X-ray output. Interlock and useful function are installed for safer and convenient operation. With combination with digital controller CO series, control via GPIB, RS-232C, RS-485 and USB is available. * Images is 3kW/4kW type. * X-ray tube is separate item. LINE UP ■ APPLICATIONS X-ray non-destructive inspection Օ XRD(X-ray Diffraction) XRF(X-ray Fluorescence Analysis) Output Voltage Output Current Output Power Model -30kV 20mA 600W XPg-30N20 40mA 1200W XPg-30N40 -40kV 15mA 600W XPg-40N15 30mA 1200W XPg-40N30 -50kV 12mA 600W XPg-50N12 24mA 1200W XPg-50N24 -60kV 10mA 600W XPg-60N10 20mA 1200W XPg-60N20 80mA 3000W XPg3-60N80 107mA 4000W XPg4-60N107 -100kV 6mA 600W XPg-100N6 10mA 1000W XPg-100N10 -160kV 4mA 640W XPg-160N4 ■ SPECIFICATIONS Input Voltage/Current ^ Input \Voltage Output \. Power \ 10 30 100VAC* 120VAC 200VAC 240VAC 200VAC* ח 220VAC 600W 640W 13A 6.5A - 1000W - 11.5A - 1200W - 13A - 3000W - 20A 11A 4000W - 25A 15A Temperature Coef. 50ppm/ °C Filament 10V 5A AC(except 3000W and 4000W model) 12V 5A AC(3000W and 4000W model) stand-by 0.5A Filament limit is variable with 10-turn potentiometer on rear panel Metering Output voltage : 3 !4-digit digital meter -1999 Output current : 3 %-digit digital meter 1999 Monitor Output Voltage monitor:0V to 10V (output impedance 1 ki typ.) Current monitor:0V to 10V (output impedance 1k 2 typ.) Protections Protection against over voltage, over current, output short circuit, Filament protection, arc and over temperature. Disable Hv output after AC power line recovery. Other Functions Remote ON/OFF switch (outside relay) Interlock (outside relay) Output status signal (inside relay) Output Connector 30kV to 60kV : Federal Standard 75kV 3-pin 100kV, 160kV : European Standard R24 Temperature Operating: 0°C to + 40°C Storage:-40°C to +85°C Humidity 0% to 80% RH (no condensing) Accessories AC line input cable 2.5m (flying lead) (1) Instruction Manual (1) -y^These specifications are at the maximum rated output after a 2Hr warm-up period unless otherwise specified. Output Control option Local mode : Voltage front panel 10-turn potentiometer Current front panel 10-turn potentiometer Remote mode : Voltage external voltage source (Vcon) 0Vdc to 10Vdc (input impedance greater than 1M Q ) or by external 5k2 potentiometer Current external voltage source (Icon) 0Vdc to 10Vdc (input impedance greater than 1M 2 ) or by external 5k Q potentiometer Line : ±0.005% of maximum voltage for ±10% input line change Load : 0.005% of maximum voltage for full load change Line : ± 0.05% for ±10% input line change Load : 0.05% ±100uA for full load change Less than 0.03% rms (below 1kHz) Less than 0.7% rms (over 1kHz) 0.01%/8Hr Voltage Regulation Current Regulation Ripple Stability
"