Compact & High Power HV Power Supply
Compact / High power
W series
1kV to 40kV/
120W, 200W, 300W, 350W
> Compact · Light weight
> Remote control · monitor
> CC · CV automatic crossover
> High efficiency
> Full protection for output short circuit and arc
> Wide output lineup
APPLICATIONS
* Electron Beam / Ion Beam
* Electrophoresis / Bio
* Automatic Test Equipment
* X-ray Inspection System
* Capacitor Charge
SUMMARY
The W series is a compact, high power module with AC input. It is best suited for CRT evaluation, x-ray systems, and capacitor
charging applications. Equipped with full remote control capabilities and monitors, it features a wide range of outputs from 500V
to 40kV / 120W to 350W.
LINEUP
Output Voltage
(kVdc)
0 to 0.5
0 to 1
0 to 1.5
0 to 3
0 to 5
0 to 10
0 to 20
0 to 30
0 to 33
0 to 35
0 to 40
120W
Output Current
200W
(mA)
Model
Ripple
0 to 240
0 to 120
W1-0.5*
W1-1*
0 to 40
0 to 24
0 to 12
0 to 6
0 to 4
0 to 3.5
0 to 3.3
0 to 3
W1-3*
W1-5*
W1-10*
W1-20*
W1-30*
W1-33*
W1-35*
W1-40*
Output Current
(mA)
Model
Ripple
0.2%
0.2%
0 to 400
0 to 200
W2-0.5*
W2-1*
0.5%
0.2%
0.2%
0.2%
0.2%
0.2%
0.5%
0.5%
0.5%
0.5%
0 to 67
0 to 40
0 to 20
0 to 10
0 to 6.7
W2-3*
W2-5*
W2-10*
W2-20*
W2-30*
0 to 5
W2-40*
(p-p)
(p-p)
300W to 350W
Output Current
Model
(mA)
Ripple
(p-p)
0.2%
0.2%
0.2%
0.2%
0.5%
0 to 700
0 to 350
0 to 200
0 to 117
0 to 70
0 to 35
0 to 17.5
0 to 11.7
W3-0.5*
W3-1*
W3-1.5*
W3-3*
W3-5*
W3-10*
W3-20*
W3-30*
0.5%
0.3%
0.3%
0.3%
0.3%
0.3%
0.3%
0.5%
0.5%
0 to 8.7
W3-40*
0.5%
*P for Positive, N for Negative Polarity
P
SPECIFICATIONS
Input Voltage
AC115V ±10% 50/60Hz
Protection
Output Control
External control voltage 0 to 10V or external
5k potentiometer
Protection against overvoltage, over current,
short circuit, arc and over temperature
Efficiency
80% typ.
Voltage
Regulation
Line : ±0.02%(of max voltage for Input ±10% change)
Load : 0.02%(of max voltage for full load change)
Temperature range Operating : 0 to + 50°C
Storage : -40 to + 85°C
Current
Regulation
Line : ±0.1%(of max current for Input ±10% change)
Load : 0.2%(of max current for full load change)
Humidity
20 to 80%RH(no condensation)
Stability
0.02%/Hr, 0.05%/8Hr(at voltage operation)
0.05%/Hr, 0.1%/8Hr(at current operation)
Accessory
HV shielded output cable(flying lead) 2.5m(1)
AC input cable 2.5m(1)
Fixing screws control connector D-sub 25pin.
Other function
• Voltage, Current Program(0 to 10V, 0 to 5k)
• Voltage, Current Monitor(0 to 10V)
• HV ON/OFF
• Interlock
• HV status
• 10.24V reference
Temperature coef. 200ppm/°C(at voltage operation)
500ppm/°C(at current operation)
Monitor
0 to 10V, ±1%(at max rated output)
Remote switch
ON/OFF
Short = HV ON, Open = HV OFF
*These specifications are at the maximum rated output after a warm-up period unless otherwise specified.
The external appearance and specifications of all products shown in this catalog are subject to change without notice.
"