ECO-STAR 25 - 500 pages
CAPACITIES
ECO-STAR 25 - 50
60 Hz Aggregate Drying Ratings
Natural Gas
Burner
Model
ES 25
ES 50
Maximum
Capacity
(MM Btu/hr)
37
63
Main Air
Flow
(scfh)
458,000
766,000
Natural Gas
Flow
(scfh)
36,200
60,500
Capacity
w/FGR
(MM Btu/hr)
30
50
No. 2 Fuel Oil
(Low Pressure Atomization)
Burner
Model
ES 25
ES 50
Maximum
Capacity
(MM Btu/hr)
36
60
Primary Air
Flow at 36 osig
(scfh)
20,000
20,000
Main Air
Flow
(scfh)
458,000
766,000
No. 2
Fuel Oil Flow
(gph)
258
425
No. 2 Fuel Oil
(Compressed Air Atomization)
Burner
Model
ES 25
ES 50
Maximum
Capacity
(MM Btu/hr)
Compressed Air
Flow at 60 psig
(scfh)
Consult Hauck
Consult Hauck
Main Air
Flow
(scfh)
No. 2
Fuel Oil Flow
(gph)
Liquid Propane
Burner
Model
ES 25
ES 50
Maximum
Capacity
(MM Btu/hr)
39
64
Primary Air
Flow at 36 osig
(scfh)
20,000
20,000
Main Air
Flow
(scfh))
458,000
766,000
LP
Flow
(gph)
425
700
Capacity
w/FGR
(MM Btu/hr)
31
51
(Application Notes on Reverse Side)
In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.
HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051
1/06
www.hauckburner.com
Fax: 717-273-9882
ES-2
"