HY-OPTIMA 1700 Intrinsically Safe Process Hydrogen Analyzer Data Sheet0 pages
2scan
nnnnHydrogen is the future, we can sense it! ™
nnnnTechnical Data and Specifications
nnnnHY-OPTIMA™ 1700 Intrinsically Safe In-line Process Hydrogen Analyzer
nnnnDescription
nnnnH2scan's HY-OPTIMA™ 1700 in-line, real time hydrogen-specific process analyzers are designed for ease of use,
nnnninterface flexibility and true process control. The HY-OPTIMA 1700 is an intrinsically safe device that incorporates
nnnnour patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative
nnnnhumidity and temperatures up to100°C. The HY-OPTIMA™ 1700 is ideal for process gas streams containing virtually
nnnnno contaminants and where real time continuous measurements of hydrogen can increase process plant efficiencies,
nnnnimprove diagnostics and enhance maintenance management translating into higher profitability.
nnnnPerformance
nnnnHydrogen Sensitivity Range:
nnnn0.5% to 100% hydrogen by volume at 1 ATM
nnnnResponse Time: T90 < 30 sec
nnnnIngress Protection: IP64 capable
nnnnRecommended Verification Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnAccuracy(*):
nnnn± 0.3% absolute for 0.5 to 10% H2
nnnn± 1.0% absolute for 10 to 100% H2
nnnnDrift/week:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnRepeatability:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnLinearity:
nnnn± 0.2% absolute for 0.5-10% H2
nnnn± 0.4% absolute for 10-100% H2
nnnnOperating Conditions
nnnnOperating Humidity: 0% to 95% RH
nnnnFlow Rate: 0.1 slpm to 50 slpm
nnnnPressure: 0 to 7 bar gauge, 0 to 100 psi gauge
nnnnProcess Gas Temperature Range: -20°C to 100°C
nnnnOperating Temperature Range: -20°C to 40°C
nnnnStorage Temperature Range: -40°C to 50°C
nnnnCalibration Background Gas: Nitrogen
nnnnIncluded Accessories
nnnnIntrinsically Safe Power Barrier
nnnnArmored Power / Analog Cable: 4 m
nnnnCalibration Cup
nnnnOptional Accessories_
nnnnInterface Options
nnnnPower Barrier Input Voltage: 24 VDC nominal
nnnnPower Barrier Input Voltage Range: 20 VDC to 28 VDC
nnnnIntrinsically Safe Sensor Input Voltage: 10 VDC
nnnnSensor Input Voltage Range: 5 VDC to 28 VDC
nnnnInput Power: 10 W
nnnnAnalog Output: 4 mA to 20 mA
nnnnSerial Communication: RS422
nnnnSingle Channel Intrinsically Safe Analog Output Barrier
nnnn(with or without relays)
nnnnSingle Channel Intrinsically Safe RS422 Serial Interface
nnnnBarrier
nnnnSerial Interface Cable: 4 m (custom lengths available)
nnnnArmored Power / Analog Cable (custom lengths
nnnnavailable)
nnnnAdapter Fittings
nnnn1/2
nnnnCertifications
nnnnC € 0359 ^X/
nnnnII 1 G, Exia II H2, d+d IIBT3
nnnnII 2 G, Exibll H2, ibdllBT3
nnnnITS07ATEX25634X
nnnnn. MNPT thread
nnnn/2in. FNPT thread
nnnn8 SAE/MS thread size
nnnn.. and many other industry standards
nnnnDimensions
nnnnTotal Length: 10.3 in.
nnnnLength of Enclosure: 6.8 in
nnnnLength of Tube: 2.9 in
nnnnWidth: 3.4 in.
nnnnDepth: 1.4 in.
nnnn* Sensor performance specifications are only valid for units configured for a maximum 65°C dry process stream temperature. All figures
nnnnassume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The
nnnnaccuracy is specified for serial port output only.
nnnnHY-OPTIMA is a registered Trademark of H2scan
nnnnSpecifications subject to change without prior notice.
nnnn90000010 R5
nnnn27215 Turnberry Lane, Unit A, Valencia CA., 91355
nnnnTel: 661-775-9575, Fax: 661-775-951
nnnnEmail: sales(5).h2scan.com, Website: www.h2scan.com
"