HY-OPTIMATM 2700 Explosion Proof In-line Hydrogen Process Analyzer
Description
H2scan’s HY-OPTIMATM 2700 real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility
and true process control. The HY-OPTIMATM 2700 uses a solid-state sensor that is configured to operate in process gas
streams. The HY-OPTIMATM 2700 is ideal for hydrogen production and petrochemical applications where real-time
measurements can enhance process plant efficiencies, diagnostics and maintenance management.
Operating Conditions
Hydrogen Sensitivity Range:
0.5% to 100% hydrogen by volume at 1 ATM
Response Time: T90 < 30 sec
Ingress Protection: IP64 capable
Recommended Verification Interval: 90 days
Product Life Expectancy: 10 years
Accuracy(*):
± 0.3% absolute for 0.5 to 10% H2
± 1.0% absolute for 10 to 100% H2
Drift/week:
± 0.2% absolute for 0.5 to 10% H2
± 0.4% absolute for 10 to 100% H2
Repeatability:
± 0.2% absolute for 0.5 to 10% H2
± 0.4% absolute for 10 to 100% H2
Linearity:
0.2% absolute for 0.5-10% H2
0.4% absolute for 10-100% H2
Operating Humidity: 0% to 95% RH (non-condensing)
Flow Rate: 0.1 slpm to 50 slpm
Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge*
Process Gas Temperature Range: -20ºC to 100ºC
Operating Temperature Range: -20ºC to 55ºC
Storage Temperature Range: -30ºC to 80ºC
Calibration Background Gas: Nitrogen
*ATEX version: process gas pressure 1.1 ATM Max.
Adapter Fittings
¾” Union Tee Compression
Dimensions
Width: 13.8 cm (5.4 in)
Length: 19.2 cm (7.5)
Depth: 13.0 cm (5.7 in)
Interface Options
Input Voltage Range: 90 VAC to 240 VAC
Input Power: 15W
Analog Outputs:
Output Currents
4 mA to 20 mA
0 mA to 20 mA
User-specific mA range
Serial Communication Options: RS232 or RS422
Relay Contacts: Two programmable relays and one
fault relay with both normally open (N.O.)
and
normally closed (N.C.) contacts:
5A/240VAC
5A/ 30 VDC
For Latest Revision go to: WWW.h2scan.com
Performance
Certifications
0359
2700
UL 508, 1203
USC – Class I, Division 1, Groups B, C,
and D Hazardous (Classified)
*
Sensor performance specifications are only valid for
units configured for a maximum 65ºC dry process
stream and at 25 ºC ambient temperature. All figures
assume pressure compensation, operating in ambient
that do not contain Oxygen and are in addition to any
errors in the gasses used. The accuracy is specified for
serial port output only.
II 2 G Ex d IIB + H2 T4 Gb
Remote
UL 913
CAN/CSA C22.2 No. 157-92
Ex ia IIC T4 Ga
HY-OPTIMATM is a registered Trademark of H2scan
Specifications subject to change without prior notice
90000057 R3
27215 Turnberry Lane, Unit A, Valencia CA., 91355
Tel: 661-775-9575, Fax: 661-775-9515
Email: sales@h2scan.com, Website: www.h2scan.com