VIP5 Controller0 pages
VIP5 Controller
FEATURES
• 3 OPERATING MODES:
CYCLE, PULSE AND FLOW.
• INTEGRATED LCD – ALL OPERATING
VALUES SET BY SIMPLE MENU
PARAMETERS
• COMPLETE CONTROL AND
PROFILING OF HOW STANDBY AND
LUBRICATION OCCURS
• MULTI-CYCLE CAPABLE
• PRESSURE SWITCH MONITORING
FOR INJECTOR SYSTEMS
• PROGRESSIVE CYCLE SWITCH
MONITORING, SUCH AS DROPSA
ULTRASENSOR
• DUAL LINE PRESSURE MONITORING
ON BOTH LINES VIA P1 AND P2
INPUTS
• NPN, PNP, NAMUR AND SIMPLE
SWITCH INPUTS CAN BE
CONNECTED.
• MIN/MAX LEVEL MONITORING
• PRELUBE FUNCTION
• PULSE MODE ALLOWS BOTH
STANDBY AND LUBRICATION
PHASES TO CONTROLLED BY AN
EXTERNAL SIGNAL WHILST
MONITORING THE LUBRICATION
CYCLE SENSOR
• FLOW MODE ALLOWS THE VIP5
TO BECOME A SIMPLE FLOW AND
TOTAL FLOW DISPLAY UNIT WITH
MIN/MAX FLOW ALARMS
A FEATURE PACKED COMPACT ADVANCED LUBRICATION CONTROLLER
FOR SMALL AND MEDIUM LUBRICATION SYSTEMS
The VIP5 controller has been designed with an
extensive set of parameters that offer unrivalled
ease and flexibility for controlling and monitoring
your automatic lubrication system – from a simple
timed system, injector, progressive or dual line
system.
Three operating modes have been designed into the
VIP5 to offer control possibilities not found
elsewhere in a single, compact and affordable unit.
NO NEED FOR MANY DIFFERENT VERSIONS OF CONTROLLERS
ANY LONGER – THE VIP5 DOES IT ALL.
3 BRAND NEW OPERATING MODES:
CYCLE MODE:
This “conventional” operating mode allows the lubrication system to remain on standby either
with a time based system, an external signal or a combination of both. When using a combined
mode you can decide if the timer should initiate a Lubrication cycle or flag an alarm condition
because no signal has been detected within the timeout.
PULSE MODE:
This new operating mode allows the external signal to drive both the Standby and Lubrication
Phase whilst allowing you to connect your cycle or pressure switch to monitor that your system is
operating correctly for the entire duration of the Lubrication Phase. A Suspend Timer function
allows the system to suspend the lubrication phase if the driving external signal ceases.
This operating mode is ideal for chain or conveyor lubrication where the amount of lubrication is
determined by the movement of the conveyor, yet the correct output of lubricant is determined
by a cycle or pressure switch connected to the metering devices.
• CODED REMOTE ALARM SYSTEM
• 4..20MA LEVEL INPUT
• CONSTANT OR CONFIGURABLE
PULSED PUMP OUTPUT.
FLOW MODE:
Another new operating mode turns your VIP5 controller into a simple Flow Measuring device.
Simply set the flow value and units that each impulse represents and the VIP5 display turns into a
flow meter instantly display the flow rate going through your system.
A Minimum and Maximum Flow level can be set to give you a local and remote alarm
APPLICATIONS
• SIMPLE ON/OFF LUBRICATION
SYSTEMS
• SINGLE LINE INJECTOR OR
PROGRESSIVE SYSTEMS.
• DUAL LINE SYSTEMS.
• SIMPLE FLOW DISPLAY AND
MONITORING SYSTEM
KEEPING AN EYE ON YOUR SYSTEM:
IN ALL THE ABOVE MODES, ONCE YOU SET THE FLOW VALUE PER INPUT CYCLE YOU AUTOMATICALLY GET A
SERIES OF COUNTERS THAT LET YOU KNOW THE TOTAL FLOW IN THE LAST HOUR AND THE LAST DAY.
ADDITIONALLY A RESETTABLE AND NON-RESETTABLE COUNTER ALLOW YOU TO MONITOR TOTAL LUBRICANT
METERED SINCE INSTALLATION OR COUNTER RESET.