PY Extreme Environment Non-Contact Displacement Transducer0 pages
DISPLACEMENT
PY Extreme Environment Non-Contact Displacement Transducer
●
●
●
●
●
●
Non-contact
High radiation resistance
High temperature survival
Submersible
Stainless steel
Infinite resolution
The PY non-contact displacement transducer measures the distance between its front face and a target made
from a ferritic material. A ferritic material is one which is attracted by a magnet.
This sensor is appropriate for high temperature, high pressure and high nuclear radiation position
measurement applications. Many applications in turbines, in nuclear power stations and in research labs are
appropriate for this sensor.
There are two types of PY transducer, a single coil version (which must be used in pairs) and a double coil
version which can be used alone.
As the output of the PY is not linear, linearisation may be necessary depending on the application. Our 615
amplifier is designed for this.
The single coil displacement transducer
version must be used in pairs for example
one on each side of a rotation shaft.
Single coil version.
Maximum
measurement gap
Typical target
Type
PY102
PY106
PY152
PY156
PY252
PY256
Maximum
Operating
measurement temperature
gap
range
-364°F to
0.06''
428°F
-364°F to
0.06''
1112°F
-364°F to
0.12''
428°F
-364°F to
0.12''
1112°F
-364°F to
0.24''
428°F
-364°F to
0.24''
1112°F
20131118
Maximum
radiation
dose
A
B
C
D
E
F
G
H
100M Rad
0.47''
0.55''
0.47''
0.47''
0.33''
0.10''
0.49''
1.12''
100G Rad
0.47''
0.55''
0.47''
0.47''
0.33''
0.10''
0.49''
1.12''
100M Rad
0.59''
0.71''
0.59''
0.51''
0.35''
0.20''
0.59''
1.50''
100G Rad
0.59''
0.71''
0.59''
0.51''
0.35''
0.20''
0.59''
1.50''
100M Rad
0.98''
1.10''
0.98''
0.79''
0.35''
0.20''
0.59''
1.46''
100G Rad
0.98''
1.10''
0.98''
0.79''
0.35''
0.20''
0.59''
1.46''
1/2
www.rdpe.com/us/py.pdf
"