LIN Extreme Environment Displacement Transducer0 pages
20071120 1/2 www.rdpe.com/us/lin.pdf
Type L X
LIN52 4.1'' 0.79''
LIN56 4.1'' 0.79''
LIN152 7.2'' 1.57''
LIN156 7.2'' 1.57''
LIN252 11.2'' 2.36''
LIN256 11.2'' 2.36''
Type Range Operating
temperature range
Maximum
radiation
dose
Total weight Armature
weight
Inward overtravel
Linearity error
(% F.S.)
LIN52 ±5mm (±0.2'') -364°F to 428°F 100M Rad 5.3oz 0.2oz 0.2'' <±0.5% F.S.
LIN56 ±5mm (±0.2'') -364°F to 1112°F 100G Rad 5.3oz 0.2oz 0.2'' <±1% F.S.
LIN152 ±15mm (±0.6'') -364°F to 428°F 100M Rad 7.1oz 0.5oz 0.6'' <±0.5% F.S.
LIN156 ±15mm (±0.6'') -364°F to 1112°F 100G Rad 7.1oz 0.5oz 0.6'' <±1% F.S.
LIN252 ±25mm (±1'') -364°F to 428°F 100M Rad 8.8oz 0.7oz 1.0'' <±0.5% F.S.
LIN256 ±25mm (±1'') -364°F to 1112°F 100G Rad 8.8oz 0.7oz 1.0'' <±1% F.S.
DISPLACEMENT
LIN Extreme Environment Displacement Transducer
œ High cycle life
œ High radiation resistance
œ High temperature survival
œ Submersible
œ Stainless steel
œ Infinite resolution
These transducers are for displacement / position measurement. They make an accurate position
measurement of the movement of the armature (the sliding part) relative to the body of the displacement
transducer.
The LIN differential-inductance LVDTs are inductive (similar to an LVDT sensor) and because there is no
contact across the sensor element it is very robust.
This sensor is appropriate for high temperature, high pressure and high nuclear radiation position
measurement applications. Many applications in turbines, in nuclear power stations and in research labs are
appropriate for this sensor.
On our unguided LVDTs the armature assembly is a separate component, to make a measurement the user
must guide the armature inside the body without touching the sides. Unguided position measurement
transducers are appropriate where external guidance is available and give truly non-contact operation
Unguided version.
0.59'' 0.177'' 0.16'' 0.138''
M3 x 0.5,
0.4''