Model TA-2000 Six Channel Wall Mount Controller0 pages
M I L - R A M
T E C H N O L O G Y
no false alarms
GAS DETECTION SYSTEMS
Acrylonitrile (ACN)
Ammonia
Arsenic Pentafluoride
Arsine
Boron Trichloride
Boron Trifluoride
Bromine
Carbon Dioxide
Carbon Monoxide
Chlorine
Chlorine Dioxide
Chlorobenzene
Combustible Gas
Diborane
Dichloroethane
Dichlorosilane
Difluoromethane
Fluorine
Freon Gases, R-123, 134a, 11, 12, others
Germane
Hydrazine
Hydrogen
Hydrogen Bromide
Hydrogen Chloride
Hydrogen Cyanide
Hydrogen Fluoride
Hydrogen Iodide
Hydrogen Peroxide
Hydrogen Sulfide
Iodine
Methyl Bromide
Methyl Chloride
Methyl Iodide
Methylene Chloride
Nitric Acid Vapors
Nitric Oxide
Nitrogen Dioxide
Nitrogen Trifluoride
Oxygen
Ozone
Phosgene
Phosphine
Phosphorous Oxychloride
Silane
Sulfur Dioxide
Sulfuric Acid Vapors
Tetrachloroethylene
Trichloroethylene
And More (Call Factory)
C3H3N
NH3
AsF5
AsH3
BCl3
BF3
Br2
CO2
CO
Cl2
ClO2
C6H5Cl
L.E.L.
B2H6
C2H4Cl2
SiH2Cl2
CH2F2
F2
ALL
GeH4
N2H4
H2
HBr
HCl
HCN
HF
HI
H2O2
H2S
I2
CH3Br
CH3Cl
CH3I
CH2Cl2
HNO3
NO
NO2
NF3
O2
O3
COCl2
PH3
POCl3
SiH4
SO2
H2SO4
C2Cl4
C2HCl3
DESCRIPTION
The Model TOX-ARRAY 2000 wall-mount system, front panel
programmable, provides in any combination, up to 6 channels of
toxic, combustible and oxygen monitoring in a 9-1/4”W x 11-1/4”H x
6”D Nema 4X fiberglass enclosure.
Any combination of toxic, combustible and oxygen sensors can be
used on the TOX-ARRAY 2000. Each channel can have the RS485/4-20mA 3 or 4-wire smarter trransmitter, that features labor free
auto self-calibration, which adjusts span monthly based on life curve,
non-intrusive hands free auto gas calibration in 2 minutes, off-site
sensor calibration to replace sensors in the field without recalibration,
TOX-ARRAY 2000
Wall Mount Gas Detection Systems
remaining sensor life indicator, and replace sensor indicator, four
12-15 Amp relays option, diagnostics, backlit LCD display, peak
value, loop test and rapid warm-up. Also available with the 2-wire
loop powered smarter transmitter. MIL-RAM’s patented TOXARRAY sensors are based on time proven electrochemical technology.
A unique and innovative approach to sensor design eliminates false
alarms and is not affected by changes in temperature, humidity or
pressure and does not react with air; this eliminates zero drift. Interferences typically encountered on other detectors are avoided with the
TOX-ARRAY sensors. The result is fast, accurate and reliable
response with outstanding sensitivity and selectivity. The TOXARRAY sensors are extremely stable with a service life of greater than
3 years and are factory rechargeable. No additional electrolyte is
required during the 3+ years of life of the sensor charge.
The TOX-ARRAY 2000 offers tremendous microprocessor-based
capability, the simplified design eliminates the complexity encountered in setting up other microprocessor-based systems. It was clearly
designed with the end user in mind.
Each channel features a three-digit LED display. High, low and
trouble LEDs provide alarm status, while a buzzer provides audible
alarms at the controller.
Programmable relays offer added flexibility in area monitoring and
reduced installation cost. Discrete relays for each alarm level are
standard in the same 9-1/4”W x 11-1/4”H x 6”D enclosure.
An easy-to-read, backlit LCD prompts you for easy setup of each
channel. Push button switches enable the user to address various setup
parameters on the LCD and easily program each channel. Alarm set
points, relay assignment and function (latching or non-latching) are
easily installed for each channel.
The Model TOX-ARRAY 2000 is designed to operate from field selectable 115/230 volts AC, 50/60Hz, 12-24 volts DC. An optional
battery backup with trickle charge circuit is available as well as RS-485.