PANDAROS DC 60 pages
High-speed engine controls
for small engines
PANDAROS DC 6
Features
extended generator and
vehicle application
DATA SHeeT
Two separate speed pickups
possible
Description
Additional analogue inputs
for synchronising and
isochronous load sharing
The DC 6 is HeINzMANN’s second
generation of digital PANDAROS
controls for small- sized high-speed
engines.
Overspeed protection
This highly efficient speed governor
is based on a 16-bit microprocessor. The DC 6 control unit offers two separate
speed pickup inputs, inductive or Hall type.
Integrated CAN provides external communication. DC 6 is able to drive direct
working as well as gear-type actuators which however require the extension
module CU01. Setting torques up to 30 Nm are possible. In combination
with HeINzMANN’s small, medium and large range actuators or the Bosch
eDC™ pump DC 6
control unit provides the
ideal solution for small
high-speed engines and
turbine applications. The
advanced DC 6 hardware
is fully compatible with
any predecessor. All DC 6
software versions can be
used without any change.
Actuators
PANDAROS DC 6 is the control device for the PANDAROS family.
PANDAROS
Systems
StG
6/10
PANDAROS I
x
StG
16/30/40
StG
2005/2010/
2040/2080
StG
2005/2040-DP
x
PANDAROS III
x
PANDAROS IV
x
digital positioner
x
x
PID mapping of governors
dynamic characteristic
according to speed,
temperature and load
Idling and maximum speed
control, velocity limitation
and regulation for vehicle
applications
Fuel limitation depending
on speed, boost pressure,
temperature and further
parameters for optimal load
factor and in order to protect
the engine
Speed dependent
monitoring of oil pressure
with or without engine stop
for engine protection
Communication via CAN
PANDAROS II
PANDAROS V
PANDAROS VI
Start fuel limitation regarding
engine temperature for
optimum fuel quantity
during start and run-up
phase and reduction
of start-up smoke to a
minimum
x
x
easy parameterisation via
HeINzMANN DcDesk 2000
communication tool or hand
programmer
Governor and sensor
monitoring
error and operating data
logging