1250_Air_Bar_Static Eliminator0 pages
ANTI-STATIC
BARS
1250 AIR BAR
STATIC ELIMINATORS
The 1250 Air Bar uses low
pressure compressed air to
extend the effective static
neutralisation range of the
1250 Bar to over 500 mm.
Typical applications for the
1250-Air Bar are stopping film
sticking to rollers on packaging
machines, keeping sensors clean
and free of static, neutralising
mouldings on conveyors and
many others.
>t The 1250-Air Bar has all the
t
advantages of the 1250-S Bar t
with the assistance of an airflow t
which extends the neutralisation t
distance to over 500 mm.
>t It is used for blowing ionised
air into a restricted area, onto
a product which moves in
position or onto a
t
substantially 3-dimensional
product.
How it works:
Ionised air from a standard AC static
eliminator has a limited life - typically
about 2 seconds - before it recombines
to become ordinary air. This time scale
limits the range of static eliminator
bars - for example, the maximum range
of the standard 1250-S Bar is 150 mm.
The 1250 Air Bar uses a flow of
compressed air to transport the ions to
the static charge within 2 seconds.
Air travels at 45° across the static
eliminator bar picking up the ionisation
and transporting it to the target.
1250_Air_Bar_DS_iss4
Scotts Business Park, Bampton, Devon, GB, EX16 9DN
T + 44 (0) 1398 331114 F + 44 (0) 1398 331411
E sales@fraser-antistatic.co.uk W www.fraser-antistatic.com
© Fraser Anti-Static Techniques Ltd 2015
p1
"