TECHNICAL SPECIFICATIONS
ML210
Supported Sensors
Multi-Mag
FPI-Mag
SPI-Mag 1” & 2”
Flo-Pipe Model FP180 & Model FP181
Sewer-Mag
Mag-Meter MS1000 & MS2500
Enclosure
Material:
Protection rate:
Dimensions:
Weight:
Painted aluminium die casting
IP67 (when cover is closed & tighten)
140 x 160 x 140 mm (W x D x H)
3,10 kg
General Attributes
Programming:
Serial interface :
Display:
Data logger:
Data storage:
ML210
Stationary converter for full pipe
flowmeter sensors
The ML210 is a stationary converter for full pipe
sensors. It is either AC or DC powered. The ML210 is
suited for connection to a large range of sensors for
full pipe measurements. Refer to list beside.
When combined with one of the above mentioned
sensors the ML210 with its 4-20mA and contact
closure outputs becomes a powerful full pipe
flowmeter and data reporting system.
The ML210 provides users with a reliable solution for
full pipe stationary flow monitoring applications. The
standard model includes: an IP67 enclosure; a 3-key
numerical key pad; a graphical backlit LCD display,
100-265 VAC or 10-36 VDC power supply, 1
0/4...20mA output and 2 Pulses/Alarm outputs.
3 membrane keys
RS485 (opt.) or RS232 (opt.)
Back lit graphic display 128x64 pixels
32 values + 64 alarm events (other opt.)
Eeprom stored measuring values on
power failure
Full scale value:
0.4…10m/s
Galvanic isolation:
All the inputs/outputs are galvanically
isolated from power supply up to 500V
Bi-directional:
Yes with exception of FPI-Mag & MultiMag (back flow indication only)
Dual range:
YES
Diagnostic function:
YES
Emtpy pipe detection: YES
Batch function:
YES
CE certification:
YES
Outputs / Inputs
Pulse/Alarm output:
Analog output:
Digital input:
Two programmable function (pulses,
alarms) 1,25 KHz, 100 mA, 40 Vdc (+2
opt.)
One 0/4…20mA – RL = 1000Ω (+1 opt.)
One programmable function (totalizer
reset)
Measurements tolerance
Flow rate (volume) = +/- 0.05 % v.l.
Out 4/20 mA = +/- 0.08% v.l.
Frequency out = +/- 0.08% v.l.
Power Supply
AC:
90 -265 VAC / 45-60 Hz (20W/25VA) Imax 0.25 A or
DC:
10-35 VDC (20W) Imax 1.5 A
AC or DC must be specified at time of ordering
Ambient Conditions
Operating temp.:
Note:
-20°C to +60°C
Not all options are combinable. Other options may be
available. Please refer to Flow-Tronic for more information.
Specifications are subject to change without notice
Updated: 31/08/2012 by BS