M-Series Field Verification Device0 pages
M-Series® Mag Meter
Field Verification Device
OVERVIEW
The Field Verification Device is a portable test device for the Badger
Meter M-Series® of electromagnetic flowmeters. The M-2000 and
the M-5000 meters can be tested using this device.
With the Field Verification Device, accurate verification of meter
functionality is assured without taking the meter out of the
pipeline (“wet” test) and interrupting functionality. Meter diagnosis
and calibration can be performed on-site. A “dry” test (removing the
meter and bench-testing) can also be performed. The complete
verification test consumes approximately 20 minutes and results
can be downloaded to a Microsoft® Windows® XP or Vista® personal
computer.
FEATURES
•t Determines if the M-Series meter is within one percent of the
original factory calibration.
•t Verifies the functionality of all of the meter’s inputs and outputs.
•t Measures electrode resistance and integrity.
•t Measures coil resistance and integrity.
•t Measures coil insulation resistance.
ACCURACY
•t Measures current and frequency at previously selected flow rate.
Input Gain: +/-0.1 %
•t Evaluates the signal processing functionality.
•t Verifies that there is no high-voltage noise disturbing the coil
circuit.
Excitation Coil Current: 20-400mA +/- 0.1 %
Amplifier Excitation Coil Frequency: 50/60Hz) +/- 1 %
Analog Outputs Current: 4-20mA +/- 0.1 %
•t Provides certified printout showing test results.
Digital Outputs: 1Hz/20 kHz) - 0.1 %
Coil Resistance: 40-120Ohm +/-1 %
•t Capable of storing 100 meter tests
ACCESSORIES
•t Test cable for M-2000 connection
Detector
Electrode Resistance (against ground: 100kOhm10MOhm) +/-10 %
Coil Insulation (against ground): 100kOhm10MOhm) +/-10 %
•t Test cable for M-5000 connection
•t AC charger with EU/US connection adaptors
•t Automobile utility DC power supply connector
•t PC communication cables to Verification Device
•t Pelican suitcase for transport
ITB-194-01 (12-10)
Technical Brief