Recordall® Compound Series with Two RTRs0 pages
Recordall® Compound Series with Two RTRs
Hi-Lo Harness
Band
Waterproof Connector
DESCRIPTION
The Hi-Lo Harness is designed to work with the Recordall
Compound Series Meter with two Recordall Transmitter
Registers (RTR®). This harness provides remote separate
totalization information from each of the RTRs.
SPECIFICATIONS
Temperature
32…140° F (0…60° C)
Resolution
1/10th of test circle of RTR
Cable Length (Standard) 75 ft.
OPERATION
When connected to the output connector from the two
RTRs, the Hi-Lo Harness provides two separate output
signals. One signal is the equivalent totalization from
the high side (turbo) of the meter, and the other is the
equivalent totalization from the low side (disc) of the meter.
The Hi-Lo Harness is attached to the two RTR output using
a waterproof connector. The wires are 22 gauge stranded
twisted pair conductors. The conductors are shielded,
including a drain wire. The red conductor is positive polarity
and the black conductor is negative polarity. There is a band
attached to the wire that is to be connected to the high side
of the meter.
RCS-DS-01317-EN-02 (November 2014)
Product Data Sheet
"