TrueTILT? Wide Range 0717-4323-990 pages
Patent 6,249,984
DATA SHEET
Description
Applications Include
The 0717-4323-99 True Tilt™ Sensor represents a
new advancement in electrolytic sensor technology.
Robust all metal construction provides durability as
well as superior dimensional tolerances, which equates
to excellent sensor-to-sensor electrical performance.
This sensor is ideal for economical, commercial market
applications requiring high production quantities and
first rate accuracy
●
●
●
●
●
●
●
●
●
●
Angle Range (max)
Linear Range
Resolution
Repeatability
True Tilt™
Wheel Alignment
Navigation and GPS Compensation
Lift Platform
Tip Protection
RV Leveling
Antenna Positioning
Physical Dimensions
±50°
±15°
±0.005 degrees
± 0.1 degrees
Operating Specifications
Operating Range
Linear Range
Null Current (max.)
Null Impedance
Repeatability
Resolution
Symmetry (typ.)
Null Offset1 (max)
Mech. Crosstalk / Deg. (to 20°)
Temperature Coefficient
Null
Scale
Stability @ 24 hrs
Operating Temperature
Storage Temperature
Time Constant (1)
Material
±50°
±15°
0.2mA (continuous)
55K Ohms (25°C)
±0.1°
≤0.005°
5%
±3.0°
±0.025°
20 arc sec / °C
0.1% / °C
±0.1°
-40°C to + 85°C
-55°C to + 100°C
≤ 100 msec
Magnetic
Diameter – Cap
Diameter – Flange
Lead length
Lead diameter
Lead spacing (center to center)
0.325” (8.25mm)
0.360” (9.14mm)
0.20” (5.0mm)
0.020” (0.5mm)
0.1” (2.5mm)
Linearity Specifications
Range (0° to 3°)
Range (3° to 8°)
Range (8° to 15°)
Linearity ≤ 0.01°
Linearity 2%
Linearity
3%
Sensor Test Circuitry
1 Difference between electrical and mechanical null
NOTE: Output sensitivity’s scale factor may be modified to
Individual requirements upon special order.
Tests were conducted by exciting the outer electrodes of the
sensor in a single axis mode using the Fredericks Universal signal
conditioner. Output curve and linearity specifications are shown
above. Information on electrolytic tilt sensor signal conditioning is
available on the Fredericks web site at www.frederickscom.com.
Caution! – Ensure that all test and operating circuits
are entirely free of direct current. Direct current will
cause
level damage and/or instability
Note! – The housing (center pin) is the active output
signal. The unit must be electrically isolated.
The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067
Tel: 215.947.2500 l Fax: 215.947.7464 l Email: sales@frederickscom.com l www.frederickscom.com
0717-4323-99data sheet Revision: A