C0814D0 pages
THE
PRODUCT LINE
www.ibus.com
www.ibus.com
C0814D
14-Slot CompactPCI® Platform
The C0814D is the first I-Bus enclosure to feature our fail-safe OptiCoolTM design
Ordering Information
Specifications
C0814D
8U, 14-slot CPCI enclosure with
4-drive bay
Dimensions
8U Height
• 14" x 17.1" x 12" (hwd)
• 356 x 434 x 304 mm
--------------------------------------------------Power Subsystem Options
PSU-AC
Four 200W N+1 AC power supplies
PSU-DC
Four 200W N+1 -48VDC power supplies
PIM-AC
Redundant AC isolated input modules
PIM-DC
Redundant DC isolated input modules
PIM-UPS
AC input module and an embedded UPS
kit
--------------------------------------------------Control & Monitoring Options
IBC-2501
Chassis Management Controller, IPMI
v.1.0 compliant Module.
Enclosure
• 14-slot card area
• 4 SCA SCSI vertical drive bays
• 4 power supplies
• 2 Rear power input bays
• ESD grounding locations (front & rear)
• Alarm panel used with optional Chassis
Management Controller (CMC)
• Front power switch
• Designed to meet NEBS/ETSI standards
Systems
Available as systems using:
• IBC 2600, 2601 & 2801 PIII based SBCs
• CP 1500, 20xx SPARC based SBC
• Windows NT & 2000, Solaris and Linux
operating systems
Backplane
• Integrated 14-slot backplane
• Supports one-slot system master (slot#1)
• 13 full hot-swap I/O slots
• 13-slot continuous H.110 backplane
• Rear low-profile pallet bridge between slots 7&8
• Dual power input connectors
Drive Expansion
• Four SCSI SCA drive shuttles
• Drives Hot-swap from front
• Rear external SCSI connector and terminator
Fail-Safe OPTICOOLTM Cooling
• Patented push-mix-pull cooling technology
• 8 + 2 fan, hot-swap cooling array in air intake
• Patented air flow mixing and directing tray
• 3 individually hot-swap blowers
• Optional blower and fan speed control with
I-Bus CMC
Power Supply Subsystem
• Four Hot-swap redundant power supplies
• N+1 Redundant (N=3) 200W supplies
• Dual feed power inputs
• Input Voltage: 90-132/180-250 VAC autoranging, Optional -48VDC
• Output Power: +3.3V@30A, +5V@25A,
+12V@6A, -12V@0.5A (each supply)
• Combined power of +5 and +3.3V not to
exceed 35A total per supply
Power Input Subsystem
• Dual redundant AC or DC input modules
• 10 millisecond failover time
• 3Ux 80mm deep each module
• Single AC input with embedded UPS option
Operating Environment
• Temperature: 0 to 40º C
• Humidity: 5% to 85% @40ºC (non-condensing)
• Shock: 10g @11mS
• Vibration: 0.25G @2-100Hz, 1.5g@100-500Hz
Standards Compliance
• PICMG 2.0 R 3.0, PICMG 2.1 R 2.0,
PICMG 2.5 R 1.0, PICMG 2.9 R1.0,
PICMG 2.10 R 1.0, PICMG 2.11 R 1.0,
• ESD: CE
• EMI: CE, FCC, UL/CUL
• Safety: UL/CUL, CE, CB
• NEBS
01-20-05 Rev. F
"