Measuring Sensors0 pages
www.precitec.com
White Light Sensors
Sensor
CHRocodile 2 S
CHRocodile 2 SE
CHRocodile E
CHRocodile S
CHRocodile SE
CHRocodile M4
CHRocodile M10
CHRocodile
XL, X, DX, H
application
distance, thickness
measurements / second
32 - 20000 (2 S)
32 - 66000 (2 SE)
32 - 4000
32 - 2000 (S)
32 - 4000 (SE)
32 - 4000
15000 / number of active
channels
100 - 14000 1)
interferometric measuring range 2)
3 µm - 180 µm
2 µm - 250 µm
3 µm - 180 µm
2 µm - 250 µm (HR)
not implemented (HS)
not implemented
not implemented
9 x 10 -5 x upper
measuring range limit (HR);
12 x 10 -5 x upper
measuring range limit (HS)
9 x 10 -5 x upper measuring range limit
chromatic measuring range
depends on optical probe
pitch error 3)
< 10 -3
linearity error 3)
< 3.3 x 10 -4 x upper measuring range limit
resolution
10 -7 x upper measuring
range limit / IEEE 754 single
precision floating point
reproducibility
9 x 10 -5 x upper measuring range limit
number of measuring channels
1
1
1
1 to 4
1 to 10
1 (CHRocodile X, XL, H);
2 (CHRocodile DX)
synchronization with
external devices
trigger input
synchronizing output
encoder inputs
1
1
5
1
1
3
1
1
3
per channel
1
1
3
1
1
3 (optional 5)
1
1
3 (optional 5)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
CHRocodile H
CHRocodile DX
CHRocodile X
CHRocodile XL
interface
USB
–
RS-232
–
RS-422
2 x analog (-10 V up to +10 V, 16 Bit)
–
2 x analog (0 V up to 10 V, 16 Bit)
LVDT
Ethernet
transfer rate
RS-232 (9600 - 921600 Baud)
RS-422 (9600 - 921600 Baud)
USB: virtual comport (921600 Baud)
Ethernet (100 Mbit)
light source
Halogen lamp
LED
Xenon short arc lamp
Xenon plasma light source
10 -7 x upper measuring range limit
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Optical Sensors
–
optical fiber 4) 2 m - 40 m
multi mode fiber
fiber connector
E 2000
operating temperature
+5°C up to +50°C
dimension
width
height
depth
220 mm
110 mm
125 mm
260 mm
115 mm
310 mm
200 mm
100 mm
93 mm
19"
3 RU
306 mm
360 mm
160 mm
400 mm
weight
2 kg
5 kg
1.1 kg
10 kg
11 kg
11 kg (X, H);
8 kg (DX);
13 kg (XL)
supply voltage
16 - 30 V DC
(with separate power supply
90 - 264 V AC)
85 - 264 V AC
47 - 63 Hz
16 - 30 V DC
(with separate power supply
90 - 264 V AC)
85 - 264 V AC
47 - 63 Hz
90 - 264 V AC
47 - 63 Hz
100 - 240 V AC
47 - 63 Hz
rated power
20 W
140 W
10 W
135 W (+ 5 W per added
channel)
150 W
110 W (XL); 120 W (X);
150 W (H); 55 W (DX)
note
high speed measurements, automatic light
control; CHRocodile 2 SE:
external coupler
LED version has
automatic light control
outstanding price/
performance ratio,
automatic light control
modular multi channel
system, different combinable module types
multi channel sensor
fast measurements
available on dark surfaces
order number
5007530 (S)
5007531 (SE)
5000287
5001783 (S)
5005134 (SE)
5002559 (Modul High
Resolution (HR))
5002520 (Modul High
Sensitivity (HS))
5001635
5005024 (X);
5005135 (XL);
5005138 (DX);
5005052 (H)
CHRocodile X, XL, H:
360 mm
160 mm
400 mm
DX: 19“ x 2 RU x 360 mm
P R E C IT E C T H E S M A R T W AY TO M E A S U R E
"