HOGEN S SERIES HYDROGEN GENERATION SYSTEM0 pages
Technical Specifications
HOGEN® S Series
Hydrogen Generation Systems
S10
S20
S40
DESCRIPTION
On-site hydrogen generator in an integrated, automated, site-ready enclosure.
Load Following operation automatically adjusts output to match demand.
ELECTROLYTE
Proton Exchange Membrane (PEM) - caustic-free
HYDROGEN PRODUCTION
Net Production Rate:
Nm3/hr @ 0°C, 1 bar
SCF/hr @ 70°F, 1 atm
SLPM @ 70°F, 1 atm
kg per 24 hours
0.265 Nm3/hr
10 SCF/hr
4.7 SLPM
0.57 kg/24hr
0.53 Nm3/hr
20 SCF/hr
9.4 SLPM
1.14 kg/24hr
Delivery Pressure - Nominal
13.8 barg (200 PSIG)
Power Consumed per
Volume of H2 Gas Produced
1.05Nm3/hr
40 SCF/hr
18.8 SLPM
2.27 kg/24hr
6.7 kWh / Nm3
17.6 kWh / 100 ft3
Purity (Concentration of Impurities)
99.9995% (Water Vapor < 5 PPM, -65°C (-85°F) Dewpoint,
N2 < 2 PPM, O2 < 1 PPM, All Other Undetectable)
Turndown Range
0 to 100% net product delivery
Upgradeability
N/A
DI WATER REQUIREMENT
Rate at Max Consumption Rate
Temperature
Pressure
Input Water Quality
0.235 L/hr (0.065 gal/hr)
0.47 L/hr (0.13 gal/hr)
0.94 L/hr (0.25 gal/hr)
5°C to 35°C (41°F to 95°F)
1.5 to 4 barg (21.8 to 58.0 PSIG)
ASTM Type II Deionized Water required, < 1 micro Siemen/cm (>1 megOhm-cm)
ASTM Type I Deionized Water preferred, < 0.1 micro Siemen/cm (> 10 megOhm-cm)
www.protononsite.com | T 203.949.8697 | F 203.949.8016 | Proton OnSite 10 Technology Drive Wallingford, CT 06492 | customerservice@protononsite.com
"