GTM21089 SERIES0 pages
GTM21089 SERIES-19W
0-19 Watts, DeskTop Universal Input, Single Output
Family, Medical Class I & II, IEC/EN 60601-1 3rd Edition
ISO 9001:2008
REGISTERED
Part Number Ordering System (See Page 302)
Output Plug/Cord Options (See Page 271)
INDOOR USE ONLY
ELECTRICAL SPECIFICATIONS:
INPUT VOLTAGE:
90 VAC TO 264 VAC
INPUT CURRENT:
< 0.5 A RMS AT 90 VAC INPUT
INPUT FREQUENCY:
47 HZ - 63 HZ
OUTPUT VOLTAGE:
SEE TABLE BELOW
OUTPUT CURRENT:
SEE TABLE BELOW
OUTPUT POWER (RATED):
19 WATTS MAX
OUTPUT RIPPLE (PEAK TO PEAK):
< 1% TYP
OUTPUT REGULATION (LINE/LOAD):
+ 5% FOR MAIN OUTPUT, MEASURED AT O/P CONNECTOR
LINE REGULATION:
+ 1% MAX AT FULL LOAD
TURN ON/ TURN OFF OVERSHOOT:
5% MAX 500uS MAX RECOVERY TIME FOR 25%
STEP LOAD
TURN-ON DELAY:
1 SEC TYPICAL
HOLD-UP TIME:
10 mSEC MIN AT NOMINAL INPUT AND FULL LOAD
INRUSH CURRENT:
30 A TYPICAL AT COLD START FOR N.A. (40A FOR EURO)
EFFICIENCY:
75 % TYPICAL
SWITCHING FREQUENCY:
100 KHZ TYPICAL
OVER-VOLTAGE PROTECTION:
VOLTAGE LIMITED LESS 130% OF NOMINAL VOLTAGE
OVER-CURRENT / SHORT CIRCUIT:
HICCUP WITH AUTO RECOVERY
OTHER PROTECTION:
INPUT LINE AND NEUTRAL FUSING
SAFETY APPROVALS:
MEDICAL MODELS:
CB CERTIFICATE: IEC 60601- 1:2005 (3RD ED.)
CB REPORT: IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007)
3RD EDITION AND/OR EN 60601-1:2006 + A11:2011.
2 X MOOP ISOLATION (MEANS OF OPERATOR PROTECTION)
SIQ MARK CERTIFICATE: EN 60601-1 :2006 + ALL :2011
UL 60601-1, CUL TO 22.2 NO. 601, TUV EN60601, AND
cTUVus TO UL 60601 FOR CLASS I AND CLASS II;
CE FOR EMC, PSE TO J60950, PSE TO J60950
DIELECTRIC WITHSTAND VOLTAGE:
5656 VDC (4000 VAC) PRIMARY-SECONDARY
2121 VDC (1500 VAC) PRIMARY- GROUND
LEAKAGE CURRENT:
< 100uA at 264Vac INPUT VOLTAGE
LINE SURGE:
EN 61000-4-5 LEVEL 4
EMI:
COMPLIES WITH EN55022 AND EN55011, CLASS B AND FCC
PART 15 CLASS B WHEN TESTED WITH A RESISTIVE LOAD,
BOTH CONDUCTED AND RADIATED
CE MARK:
EN55011, Group 1, Class B, EN5022 Class B, EN55011, Group
1, Class B; EN55024 / EN60601-1-2 / IEC 61000-4-3:2002;
EN55024 / EN60601-1-2 / IEC 61000-4-6:2001 ; EN55024 /
EN60601-1-2 / IEC 61000-4-8:2001; EN55024 / EN60601-1-2 /
IEC 61000-4-11:2001; EN55024 / EN60601-1-2 / IEC 61000-44:2001; EN55024 / EN60601-1-2 / IEC 61000-4-2:2001; EN55024
/ EN60601-1-2 / IEC 61000-4-5:2001; EN55024 / EN 61000-3-3
A1: 2001 / EN 61000-3-3 A1: 2001; EN55024 / EN 61000-32:2001 / EN 61000-3-2:2001.
MTBF:
GREATER THAN 200,000 HOURS AT 25°C AMBIENT
TEMPERATURE, AND NOMINAL LINE AT FULL LOAD
PER MIL-217.
OPERATING TEMPERATURE:
0° C TO 40° C
STORAGE TEMPERATURE:
-40° C TO 80° C
HUMIDITY:
0% TO 90% RELATIVE HUMIDITY
MODEL NUMBER CODE:
GT-2: INTERNAL CODE;
M: MEDICAL MODEL
1089: FAMILY DESIGNATION;
1003 TO 1948: POWER/INPUT VOLTAGE;
T: DESKTOP;
3: CLASS II WITH FUNCTIONAL EARTH (3 PRONGS)
2: CLASS II, DOUBLE INSULATED;
NOTES:
1. EACH OUTPUT CURRENT MAY VARY WITHIN IT'S
DESIGNATION RANGE, AS LONG AS OUTPUT POWER IS
NOT EXCEEDED.
2. OUTPUTS ARE AVAILABLE FROM 3.3V-48V IN 0.1V
INCREMENTS
3. (X.X) OPTIONAL FOR SPECIFYING OUTPUT VOLTAGE
DEVIATION FROM STANDARD MODEL: SUBTRACTING X.X
VOLTS FROM STANDARD OUTPUT VOLTAGE.
SEE APPENDIX “C” FOR ELECTRICAL
PERFORMANCE CURVES
OUTPUT VOLTAGE / CURRENT:
CLASS I MODELS
OUTPUT
VOLTAGE
(VDC)
OUTPUT
CURRENT
(A)
GTM21089-1003-T3
+3.3
0 - 2.6
GTM21089-1305-1.0-T3
+4.0
0 - 2.6
0-10
GTM21089-1305-X.X-T3
+5.0
0 - 2.6
0-13
GTM21089-1506-X.X-T3
+6.0
0 - 2.5
0-15
GTM21089-1509-2.0-T3
+7.0
0 - 2.0
0-15
GTM21089-1509-1.0-T3
+8.0
0 - 1.8
0-15
GTM21089-1509-X.X-T3
+9.0
0 - 1.7
0-15
GTM21089-1512-2.0-T3
+10.0
0 - 1.5
0-15
GTM21089-1512-1.0-T3
+11.0
0 - 1.3
0-15
MODEL
NUMBER
RATED
OUTPUT
POWER (W)
0-9
SPECIFICATIONS MAY CHANGE WITHOUT PRIOR NOTICE. CONSULT GLOBTEK CUSTOMER SERVICE FOR LATEST SPECIFICATIONS.
(+1.201.784.1000
w w w. g l o b t e k . c o m
93
"