Modular Temperature Controller EJ10 pages
Modular Temperature Controller
EJ1
CSM_EJ1_DS_E_8_1
In-panel Temperature Controller with Flexible
Modular Design and Wide Integration with
Host Devices
• The compact modular structure enables construction of temperature
systems optimally suited to the application.
• Connection can be made to a Programmable Controller without any
programming required, reducing the number of steps required in ladder
programming design.
• One fully universal-input Unit includes a thermocouple, platinumresistance thermometer, and analog input for easy selection and reduced
inventory requirements.
• Connect directly to the G3ZA Multi-channel Power Controller using
optimum cycle control for high-accuracy regulation with minimal noise.
• Autotuning (AT) can be used for independent heating/cooling PID control.
• Self-tuning (ST) can be used to calculate the PID constants with the step
response method.
• Up to 16 Temperature Controllers can be connected to a single
DeviceNet Communications Unit.
Supports DeviceNet Communications.
Refer to the “Safety Precautions” on
page 20.
Ordering Information
Temperature Controller
Standard Control Models
Power
supply
voltage
Name
Basic Unit
(temperature
control) *1
V1.2
No. of
control
points
24 VDC 2
supplied
from the
End Unit
4
2
HFU with
Programless
Communications
*1
None
Control
outputs
1 and 2
Voltage
output:
2 points
(for SSR
drive) *2
Control
outputs
3 and 4
Transistor
output: 2 points
(sinking)
Functions
Auxiliary
output
None
Voltage output:
2 points (for
SSR drive) *2
Current
output:
2 points
None
Communications
functions
2 *3
G3ZA connection
port: RS-485
From End Unit:
Port A or port B:
RS-485
None
Transistor
output: 2 points
(sinking)
None
Heater
Event
burnout
inputs
alarm
2
None
2
Input type
Thermocouple,
platinum
resistance
thermometer,
analog
voltage, and
analog current
selectable for
each channel.
M3 terminal
EJ1N-TC2A-QNHB
Screw-less
clamp
EJ1N-TC2B-QNHB
M3 terminal
EJ1N-TC4A-QQ
Screw-less
clamp
EJ1N-TC4B-QQ
M3 terminal
EJ1N-TC2A-CNB
Transistor
output:
4 points
(sinking)
4
Port C: RS-485 or
RS-232C
selectable.
No input
EJ1N-TC2B-CNB
M3 terminal
EJ1N-HFUA-NFLK
Screw-less
clamp
From End Unit:
Port A: RS-485
Port C: RS-422
From End Unit:
Port A: RS-485
HFU with
DeviceNet
Communications
*1
None
24 VDC
Model
Screw-less
clamp
V1.2
End Unit *1
Terminal
Transistor
output:
2 points
(sinking)
None
None
EJ1N-HFUB-NFLK
M3 terminal
EJ1N-HFUA-NFL2
Screw-less
clamp
EJ1N-HFUB-NFL2
DeviceNet
communications
Screw-less
clamp
Port A or B: RS485
Connector: Port A
M3 terminal
EJ1C-EDUA-NFLK
Detachable
connector
EJ1C-EDUC-NFLK
EJ1N-HFUB-DRT
*1. An End Unit is always required for connection to a Basic Unit or an HFU. An HFU cannot operate without a Basic Unit. External communications cannot be performed when using a Basic
Unit only.
*2. For heating/cooling control applications, control outputs 3 and 4 on the 2-point models are used for the cooling or heating control outputs.
On the 4-point models, heating/cooling control is performed for the two input points.
*3. When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately.
Functional Upgrades
Refer to page 17 for details.
Upgrade functions are supported by the indicated version ("V1.1" or "V1.2") or a higher version of the software.
Refer to the following manual for precautionary information and other information necessary to use the EJ1:
EJ1 Modular Temperature Controller User’s Manual (Cat. No. H142)
1
"