ABW - Filter Units0 pages
WOODWORKING FILTER UNITS
nnnnModel: ABW-42...ABW-104
nnnnTECHNICAL SPECIFICATIONS
nnnnCompressed air
nnnnconnection (1/2")
nnnnmax. 10bar
nnnnDrainage
nnnnProcess
nnnnControl
nnnnPower
nnnnConnection
nnnnService
nnnnCover
nnnnClean air
nnnnControl
nnnnPanel
nnnnFilter
nnnnCover
nnnnFire
nnnnExtinguishing
nnnnCover
nnnnDifferential
nnnnPressure
nnnnGauge
nnnnDrainage
nnnnOne-way valve
nnnnContaminated
nnnnair inlet
nnnnDisposal
nnnnBin
nnnnB
nnnnSTANDARD SPECIFICATIONS
nnnn• ABW-Series filter units are designed specifically for woodworking dust collection applications with one-way valve contaminated air
nnnninlet.
nnnn• ABW-Series filter units are ready to operate with their filters, fan and motor, integrated electrical control panel and automatic
nnnncleaning system.
nnnn• One-way valve contaminated air inlet protects woodworking process and tubing system from low pressure explosions generated
nnnnfrom wood dust.
nnnn• Power Connection 380/400V ~ 3P N PE - 50 Hz.
nnnn• High efficient ventilators that have backcurved blades are directly coupled to motors. The impellers are made of aluminum.
nnnn• Cartridge filters made of polyester non-woven are standard on ABW-Series filter units. They arrest 0.2 - 2 micron particles with
nnnn%99.9 efficiency. Dust Class M acc. to EN 60335-2-69. Cartridge filters have a temperature resistance up to 80 °C.
nnnn• The filter unit is equipped with automatic jet-pulse cleaning. Cleaning pressure is 4-5 bar.Control panel and the differential pressure
nnnngauge that start-and-stop jet pulse cleaning automatically are standard on ABW-Series filter units. Dust level indicator of filter
nnnnelements and pressured-air regulator are also replaced inside the filter unit.
nnnn• Static and dynamic balanced impellers with silencers ensure low sound level. Sound level varies between 67-77 dB (A) according to
nnnnfilter unit type.
nnnn• Standard models of ABW-Series filter units are produced to use inside (for indoor applications).
nnnnOPTIONS
nnnn• 220-480V ~ 60 Hz, Motor and Electrical Control Panel
nnnn• Standard air inlet is placed at right handside. On request reverse side air inlet is possible.
nnnn• Automatic fire detection and extinguishing system
nnnn• Flanged fitting for clean air-outlet to exhaust the clean air outside.
nnnn* Outdoor Application
nnnn-Electrical control panel temperature control with automatic heating.
nnnn-Additional water resistant cover for control panel.
nnnn-Pre-painting preparation against corrosion with galvanize coating for steel parts.
nnnn-UV and weather conditions resistant electrostatic polyester powder painting.
nnnn@ Ongoing product development may subject the technical specifications to alterations without notice.
nnnnVANTFRM GOSB 800 Sok'No: 4 Tel : 0262-751-05-94 web : www.vanterm.com Tarih : 30.08.2012
nnnnVAAIN I l_rAIVI /"V\p. Gebze/ Kocaeli Faks : 0262-751-13-50 e-mail: info@vanterm.com Res. No : 425.00.201
"