V100E0 pages
Model: V100E
nnnnVALVE ACCESSORIES & CONTROLS
nnnnELECTRO-PNEUMATIC POSITIONER
nnnn@ Budenberg
nnnnA line of pneumatic valve positioners incorporating over
nnnnsixty years of design, manufacturing and marketing
nnnnexpertise, creating one of the most durable, reliable
nnnninstruments on the market.
nnnnThis positioner can be ordered as a base pneumatic model
nnnnbut can be converted to a standard electropneumatic, IS, Ex
nnnnor Fail Freeze model in a matter of minutes, without
nnnnremoving the unit from its installation.
nnnnAccessories in the way of gauges, feedback modules or
nnnna raised indicator can be added in a matter of minutes.
nnnnMaximum modularity equals maximum flexibility and with a
nnnnsimple design and quality components, the performance
nnnnis a maximum as well.
nnnnInput Signal
nnnn4-20 mA ( Ri<250 ohms )
nnnnSupply Pressure
nnnn0.15 - 1MPa (21.8 - 145 PSI)
nnnnLinearity Error
nnnn<1.0% FS
nnnnHysteresis
nnnn<0.6% FS
nnnnRepeatability
nnnn<0.5% FS
nnnnPressure Gain
nnnn@ 600KPa (87PSI) according to ISA S75.13
nnnn750 Pout/Pin 49% Pout/Pin
nnnnAir Capacity
nnnn@ 200KPa (29PSI)
nnnn@ 600KPa (87PSI)
nnnn@ 1MPA(145PSI)
nnnn270SLM 9.5SCFM
nnnn800SLM 28.3SCFM
nnnn1350SLM 47.1SCFM
nnnnThread sizes
nnnnAir connections
nnnnElectrical entry
nnnnGauge ports
nnnn1/4"G
nnnnOptional 1/4" NPT
nnnnM20
nnnnOptional 1/2"NPT or PG13.5
nnnn1/8" G
nnnnOptional 1/8" NPT
nnnnIngress Protection
nnnnIP66 (NEMA4X)
nnnnSurface Finish
nnnnPowder Polyester
nnnnWeight
nnnn1.7Kg (3.8lbs)
nnnnOptions
nnnnVarious Spindles for different actuators
nnnnVarious cams
nnnnGauges
nnnnFeedback modules
nnnnIndicators
nnnnBleed Rate
nnnn@ 200KPa (29PSI)
nnnn@ 600KPa (87PSI)
nnnn@ 1MPA(145PSI)
nnnnTemperature Range
nnnn-40 to +85 Celsius (-40 to ■
nnnn5.7SLM
nnnn17SLM
nnnn28.3SLM
nnnn0.2SCFM
nnnn0.6SCFM
nnnn1.0SCFM
nnnn185 Fahrenheit)
nnnnPilot Valves
nnnnW1 Low Gain Pilot Valve, pressure gain 300 @ 600KPa
nnnnBleeds 33% less, air delivery 10% less than W3
nnnnW2 High Gain Pilot Valve, pressure gain >1000 @ 600KPa
nnnnBleeds 33% more, air delivery equal to W3
nnnnW3 Standard Pilot Valve, Air capacity and Bleed as left
nnnnW1 for better stability, W2 for better response & accuracy
nnnnBenefits
nnnnSimple calibration. With the non-interactive zero and span
nnnnadjustment and the external zero adjustment, calibration
nnnnis simple and time saving.
nnnnFlexibility. One housing for pneumatic or electro-pneumatic.
nnnnThe l/P can be installed or removed at any time. Multiple
nnnnmounting capability. Standard indicator allows for air to
nnnnopen or air to close operation. Flat or raised indicator
nnnnavailable. F05 standard housing with changeable drives.
nnnnBenefits
nnnnMaintenance friendly. The pilot valve assembly can be
nnnncleaned by removing one screw and can only be installed
nnnnone way - the correct way. The gauge block is standard.
nnnnI/P test point positioner loop testing.
nnnnDurable. Cast Aluminium, polyester coated housing.
nnnnStainless steel retained fasteners. Double locked stainless
nnnnsteel cam. Quality internal parts. Unique electrical compartment
nnnnfitted with an o-ring is pressure sealed by the cover.
nnnnRev-03 December 2006
nnnnDatasheet VAC-002
"