WPT - Isotropic Probes0 pages
WPT Mobile telephony probe
Measuring 900, 1800 and 2100 bands Electric Field
Specific mobile frequencies probe
Isotropic & True RMS measurement
Best sensitivity starting at 0.04 V/m
High interband attenuation
Telecommunications: the WPT probe
allows measurement of the electromagnetic
field only within the mobile telephone
spectrum, ignoring all other sources of
radiation.
GSM - 3G - LTE
E
RMS
ISOTROPIC
· ISO
lab
Frequency band
GSM900, GSM1800 , 3G, LTE
Sensor type
Isotropic, True RMS
Measurement range
0.04 – 65 V/m (RMS)
Dynamic range
> 64 dB
Sensitivity
0.04 V/m
Resolution
0.07 dB
Interband attenuation
ration
alib
Technical specifications
Iso
170
25
dited c
cre
025 ·Ac
17
>20 dB (1100 MHz)
>5 dB (2300 MHz)
Frequency response
± 3.3 dB (GSM, 3G, LTE bands)
Linearity
< ± 0.4 dB (0.2 - 50 V/m)
Isotropic deviation
< ± 1.7 dB
Calibration period
24 months (recommended)
Calibration
ISO 17025 accredited by ILAC laboratory
Operating temperature
-30ºC to +80ºC
Temperature response
±0.8 dB (-20ºC to 60ºC)
Dimensions
28.5 x 10.5 x 10.5 cm
Weight
140 g
Compatible with SMP2, MonitEM, MapEM
Safety, Quality, Service
+34 93 320 80 55
wavecontrol.com
info@wavecontrol.com