FCF-fan cleaned filter0 pages
FCF
Fan Cleaned Filter
RCF
Reverse Cleaned Filter
All FCF and RCF filters of the same size are identical, apart from
the fact that the FCF version is fitted with one or two cleaning fans.
The filter tops are divided into 10-28 cleaning chambers
with a total filter area of 122-765 m2.
The filter hoses are available in 1.6 m and 2.6 m lengths or
according to system at customers.
In the case of large dust volumes, it is recommended that two
dust hoppers be fitted. The considerable freedom of choice makes
it simple to adapt the filter to current processes and desired
cleaning requirements. The compact design makes it easy to
position in existing facilities.
HB Engineering Germany GmbH
Am Bendenpütz 11
D-539 19 Weilerswist, Germany
Tel +49 2251-77 03 45
Fax +49 2251-77 03 65
Processfilter Sweden AB
Helsingborg
Box 22 292, 250 25 Helsingborg
Tel +46 (0)42-38 65 80
Fax +46 (0)42-38 65 90
Processfilter Sweden AB
Borås
Magasinsgatan 10, 3 fl, 504 35 Borås
Tel +46 (0)33 -10 38 33
Fax +46 (0)33-10 07 33
www.processfilter.se
The Processfilter Representative:
laboratory satisfies
all the demands in
SS-EN ISO/IEC 17025
and handles measurement
of dust emissions
and gas flows.
FCF and RCF can be equipped with four
different filter tops, two sizes of filter hose
and different dust hoppers.
FCF and RCF with 1.6 m filter hoses
Size of filter top 1 1 2 2 3 3 4 4
Filter type 122-3 162-4 176-3 235-4 231-3 307-4 353-3 470-4
Number of filter chambers 10 10 14 14 18 18 28 28
Filterarea brutto m2 136 181 190 253 244 325 380 506
Net filter area m2 122 162 176 235 231 307 353 470
Total no. of filter hoses 120 160 168 224 216 288 336 448
FCF and RCF with 2.6 m filter hoses
Size of filter top 1 1 2 2 3 3 4 4
Filter type 199-3 265-4 287-3 383-4 375-3 500-4 574-3 765-4
Number of filter chambers 10 10 14 14 18 18 28 28
Gross filter area m2 220 294 309 412 397 530 618 824
Net filter area m2 199 262 287 383 375 500 574 765
Total no. of filter hoses 120 160 168 224 216 288 336 448
Filter with a single
hopper and a rotor
Filter with a single
hopper and two rotors
Double filter
with a double hopper
and one rotor
Examples of design combinations
The control panel is an integral part of
production. Programming of control
and monitoring systems takes place
with the aid of a laptop computer.
IDE´ • ART • DESIGN HB • HELSINGBORG
• Cleaning fan
2,000 Nm3/h)
for an FCF filter
• Heating unit
(175 W/m2) for
the dust box
Options: