SPECIFICA Monochromator Optical Bandwidth Wavelength Range Wavelength Accuracy Wavelength Reproducibility Self Test and Calibration Straylight Display Screen - LCD Display Scrolling Autozero Photometric Ranges Photometric Accuracy Photometric Noise Stability Multi-Wavelength Analysis Assay Program Curve Fitting and Editing Cell and Wavelength Programming Method Storage Absorbance Ratioing Peak Seek Reaction Kinetics Batch Sampling Real Time Clock Computer/printer interfaces Sample Temperature Size Weight Power Requirements | Littrow, 1200 lines/mm holographic grating 4nm - Aurius; 1.8nm Super Aurius 190-1000nm; 325-1000nm visible versions Better than ±1nm 0.1nm Automatic at switch on Typically less than 0.01% at 220 and 340nm High resolution backlit with contrast control Provides 6 screen widths for viewing plots etc. Automatic by press button Digital display of -0.3-3A, 0-200%T, 0-9999C ±0.005A or 1% whichever is greater Less than ±0.00004A (500nm RMS) Better than 0.001A/hour at constant temp. 2 and 3 wavelength methods Enter multi-wavelength formula for automatic computation and formatting of any assay Linear, quadratic or cubic; up to 30 standards Up to 8 cells and 10 wavelengths combined Up to 30 methods stored in protected memory 260/280nm or any two selected wavelengths Automatic search, baseline corrected Tabulated results, reaction plots, reprocessing 100 samples, internal control, screen display Timed and dated reports Bi-directional serial RS232 and parallel ports Displayed and set from keyboard 480 x 340 x 205mm 16.8kg Visible; 18.6kg UV; + 0.9kg with printer 110-250V, 50/60Hz; 120W/170W UV versions | HOGHftGHTS BENEFITS High Performance Scans Derivative Spectra Time Plots Assay Formula Program DataStream - Fast Data to PC Display Scrolling - 6 Screens Wide E-SEF Software Call-up Integral Printer Versions Method Storage Cell and Wavelength Programs Kinetics, Single/Multi-cell Multi-Wavelength Assays UV Lamp 1500 Hour Guarantee Self Test and Calibration Compact - Only 48cm Wide PERFORMANCE Optical Bandwidth 1.8nm Straylight 0.01% Wavelength Precision 0.1nm Stability ±0.001 A/hour Accurate to 3A Full Validation Procedures |
Optical Bandwidth Wavelength Scanning and Range Wavelength Scale Expansion Scan Speed Photometric Plotting Ranges Baseline Flatness Overlayed Spectra Spectral Reprocessing Dynamic Scan Recall Spectral Storage Derivative Spectra Multi-cell Kinetics Band Quantification Time Course Plotting | 1.8nm 1-4000nm/min; 190-1000nm Selectable by keyboard entry 1-100nm/cm Selectable by keyboard entry 1-4000nm/min Keyboard entry of limits; or automatic optimum Better than ±0.002A (300nm/min) most of range Up to 6 Spectra and derivatives with or without offsets Spectra manipulated and replotted over any range Instant, automatic recall of last 8 scans Up to 100 spectra may be stored security code protected 1st and 2nd derivatives Up to 4 or 6 cells, with with plots and reprocessing Automatic band area and height correction Plots may be reprocessed and stored | |
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change spcification without notice. | ||
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB4 6AZ ENGLAND ISO 9000 TEL: 01223 420821 FAX: 01223 420475 CERT|F|ED COMPANY E-MAIL: info@cecilinstruments.com WEBSITE: www.cecilinstruments.com |