TOUCH AND RED0 pages
SAFETY STRIPS
ACG3015 TOUCH
MECHANICAL SAFETY STRIP
L = 2 m - 35x2000x70mm
CERTIFIED EN 13849-2(2008)
CATEGORY 3
TECHNICAL DATA | TOUCH |
Electric contact capacity | 0,5A-24Vac/dc |
Operating temperature | min-10°C, max 50°C |
Maximum speed of device in movement | max 0,25 m/s* |
Protection Level | IP 44 |
* If you install TOUCH with gate leaves having a travelling speed higher than 0.25m/s, the safety norm
EN12453 cannot be abide by.
The TOUCH mechanical safety strip can be installed on
sliding or swing gates.
It can be managed through cable connections or RED radio
transmitter (pag. 83).
TOUCH is endowed with 3 micro-switches that allow the
management of the following functions:
1 ° A contact for impact's detection
2° A contact for the breakage of the steel cord
3° A contact for both, the breakage of the steel cord and
for the impact's detection in case the two previous
contacts are not functioning (as required by EN
13849-2).
Discover TOUCH Wi-Fi on page 80. It is identical to TOUCH
but with a RED radio transmitter circuit incorporated in
to the border itself!
PRIMA
RICERCA&SVILUPPO
CERTIFICATO DI CONFORMITA'
CERTIFICATE OF CONFORMITY
Ret. n. 10.027
alle prescrizioiii tecniche contenute nelle seguenti Norme e/o speciliche teciiidie
according to the technical requirements of the following Standard and/or technical specifications
EN ISO 13849-2(2008)
.•/ .>«». >.....'. I
Safely-related para of control systems
Part 2: Validation.
Category 3
die coiiferiscono presimzioiie <li conformita ai requisiti <li protezione stabiliti dalle Direttive CEE n.
2006/42/CE Annex I
which give compliance with the protection requirements stated by EC Directives n. 2006/42/CE An
Identificazione del prodotto:
Product identification :
Descrizione prodotto:
Product description:
Rif. Rapporto tecnico di prova:
Refi. Technical test report:
Rappresentante autorizzato:
Authorized representative:
TOUCH
PRESSURE SENSITIVE EDGE
MAC TR 091097-1
MAC RT100211-0
RIB Srt
Via Matteotti 162 - 25014 Castenedolo (BS)-Italy
conformity when are fulfilled all other requirements of the aforeme
of other Directive!
Faloppio, 12/02/2010
European Notified Body
Sig. Giovanni Molteni
Laboratory Manager
"