MSP-600 600W AC/DC0 pages
040-03-409-059-EH-0814.pdf
MSP-600
■
600W Single Output Medical Type
series
Features :
•Universal AC input / Full range
•Built-in active PFC function, PF>0.94
•High efficiency up to 89%
•Withstand 300VAC surge input for 5 seconds
•Protections: Short circuit / Overload / Over voltage / Over temperature
•Medical safety approved (MOOP level)
•Built-in cooling fan ON-OFF control
•Built-in DC OK signal
•Built-in remote ON-OFF control
•Standby 5V@0.3A
•Built-in remote sense function
•No load power consumption<0.8W (Note.7)
•Current sharing up to 2400W (3+1) (24V,36V,48V)
•5 years warranty
SPECIFICATION
MODEL
MSP-600-5
MSP-600-7.5
MSP-600-12
MSP-600-15
MSP-600-24
MSP-600-36
MSP-600-48
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
120A
120A
80A
53A
43A
27A
17.5A
13A
CURRENT RANGE
0 ~ 120A
0 ~ 120A
0 ~ 80A
0 ~ 53A
0 ~ 43A
0 ~ 27A
0 ~ 17.5A
0 ~ 13A
RATED POWER
396W
600W
600W
636W
645W
648W
630W
624W
RIPPLE & NOISE (max.) Note.2 100mVp-p
OUTPUT
MSP-600-3.3
DC VOLTAGE
100mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
4.3 ~ 5.8V
±2.0%
6.8 ~ 9V
±2.0%
10.2 ~ 13.8V
±1.0%
13.5 ~ 18V
±1.0%
21.6 ~ 28.8V
±1.0%
28.8 ~ 39.6V
±1.0%
40.8 ~ 55.2V
±1.0%
2.8 ~ 3.8V
VOLTAGE TOLERANCE Note.3 ±2.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
LOAD REGULATION
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC
HOLD UP TIME (Typ.)
16ms/230VAC
88%
89%
89%
41.4 ~ 48.6V
57.6 ~ 67.2V
16ms/115VAC at full load
VOLTAGE RANGE
Note.5 85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
120 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.94/230VAC
EFFICIENCY (Typ.)
78.5%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
INPUT
8.5A/115VAC
35A/115VAC
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
5V STANDBY
2500ms, 50ms/115VAC at full load
PF>0.99/115VAC at full load
82%
86%
88%
88%
5A/230VAC
80A/230VAC
Earth leakage current < 300 A/264VAC , Touch leakage current < 100 A/264VAC
μ
μ
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
5VSB : 5V@0.3A ; tolerance± 5%, ripple : 50mVp-p(max.)
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
REMOTE CONTROL
RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off
FAN CONTROL (Typ.)
Load 35± 15% or RTH2≧50℃ Fan on
WORKING TEMP.
FUNCTION
DC OK SIGNAL
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃ , 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
ANSI/AAMI ES60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3
EMC IMMUNITY
OTHERS
Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2
MTBF
138.7K hrs min.
DIMENSION
218*105*63.5mm (L*W*H)
1.57Kg;8pcs/13.6Kg/1.34CUFT
PACKING
NOTE
1.
2.
3.
4.
5.
6.
7.
8.
MIL-HDBK-217F (25℃)
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
Tolerance : includes set up tolerance, line regulation and load regulation.
The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Derating may be needed under low input voltages. Please check the derating curve for more details.
Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
No load power consumption<0.8W when RC+ & RC- (CN100 pin3,4) 0 ~ 0.8V or short.
When the input voltage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this
deviation that does not affect basic safety or essential performance.
File Name:MSP-600-SPEC 2013-12-30