valve island0 pages
VS26 Series valve islands
nnnnPlug-in Mini ISO Valves
nnnn2x2/2, 2x3/2, 5/2 and 5/3 valves
nnnnISO 15407-2
nnnnSize 26 mm
nnnn24 V d.c. or 115 V a.c. Multipole
nnnnIntegrated Fieldbus
nnnnField expandable with single add-on stations
nnnnDual spool technology
nnnnVS26G Glandless spool and sleeve for long life
nnnnVS26S Softseal spool for high flow
nnnnWide range of accessories
nnnnUL and ATEX
nnnnUniversal PNP/NPN 24 V d.c. Multipole
nnnnTechnical data
nnnnMedium:
nnnnCompressed air, filtered to 40 um, lubricated or non-lubricated
nnnnOperation:
nnnnVS26G: Glandless spool valve, solenoid pilot actuated
nnnnVS26S: Softseal spool valve, solenoid pilot actuated
nnnnMounting:
nnnnSub-base
nnnnPorts 2+4:
nnnnG1/4, NPTF 1/4, PIF 10 mm, PIF 8 mm, PIF 3/8
nnnnOperating pressure:
nnnnMaximum pressure
nnnn10 bar VS26S models and VS26G solenoid pilot actuated valves
nnnnwith internal pilot supply
nnnn16 bar VS26G solenoid pilot actuated valves with external pilot
nnnnsupply
nnnnDetails of minimum and maximum pilot pressure see overleaf.
nnnnFlow characteristics:
nnnnSeries Function C b A l/min Cv Kv
nnnnVS26G 5/2 4,27 0,16 16,04 1000 1,02 0,87
nnnnVS26G 5/3 4,27 0,16 16,04 1000 1,02 0,87
nnnnVS26S 2x2/2 4,88 0,17 18,40 1150 1,17 1,00
nnnnVS26S 2x3/2 5,21 0,20 20,05 1250 1,27 1,09
nnnnVS26S 5/2 5,63 0,20 21,67 1350 1,37 1,18
nnnnVS26S 5/3 5,63 0,20 21,67 1350 1,37 1,18
nnnnAmbient temperature:
nnnn-15°C to +50°C
nnnnMedium temperature:
nnnn-5°C to +50°C
nnnnConsult our Technical Service for use below +2°C
nnnnMaterials
nnnnBody/sub-base: die-cast aluminium
nnnnGlandless spool & sleeve (VS26G): aluminium, hard anodised,
nnnnteflon coated
nnnnSoftseal spool (VS26S): aluminium with HNBR seals
nnnnPlastic parts: POM, PA, PPA
nnnnMounting sheets/screws: steel, zinc coated
nnnnSprings: stainless steel
nnnnSandwich plates: aluminium bar material, PA
nnnnElectrical contacts: brass, tin/gold coated
nnnnPCB: glass epoxy
nnnnOrdering information
nnnnTo order please use valve island configurator
nnnnavailable at www.norgren.com
nnnnAlternatively contact Norgren for
nnnna configurator on CD or use our worksheet on
nnnnpage 22.
nnnnSee page
nnnn2
nnnn7
nnnn9
nnnn11
nnnn15
nnnn23
nnnn24
nnnnValves
nnnnAccessories
nnnnSub-bases and end plates
nnnnSandwich plates
nnnnMultipole/Fieldbus
nnnnAdd-on stations
nnnnSingle parts
nnnnValves
nnnnMultipole and
nnnnFieldbus
nnnnSandwich plates and
nnnnbases, accessories
nnnnAccessories
nnnnSub-bases and
nnnnend plates
nnnn3/06
nnnnOur policy is one of continued research and development. We therefore reserve the right
nnnnto amend, without notice, the specifications given in this document.
nnnnN/UK 5.4.160.01
"