Series 90000 pages
Specifications
Measuring
Technique:t
tt
System Performance
Measuring range:t
tt
Pathlength:t
Measurement cycle:t
tt
Repeatability:t
Linearity:t
Resolution:t
Response time:t
Calibration :t
tt
tt
0 - 500 ppm.m to 0 - 10000 ppm.m
Other ranges selectable from the keypad
0.5 to 10 m / 1.6 to 32 ft
20 Hz integrated over 2 secs.
Model 9100tt
Model 9200MKII
8 ppm or 2% of reading whichever is greater
± 3 % of rangett
±2 % of range
1 ppm
Adjustable between 2 and 250 secs.
Calibration audit, Zero calibration (clear stack)
Span calibration using ‘live’ calibration gas facility
(9200 Mk II only)
Control Panelt
Display:t
adjustable t
t
Keypad:t
2 x 16 character reflective backlit LCD with tttt
contrast control (receiver unit)
signal strength indicator (transmitter unit)tt
9 keys for data input, diagnostics, setup and calibrationt
Environmental
Temperature range:t
Flue gas temperature range:t
Environmental rating:t
-30 to +55 °C / -22 to 131 °F
up to 370 °C / 700 °F
IP65 / NEMA 4t
Compliance
Safety:t
EMC:t
Conforms to EN61010
Conforms to EN50 081 and EN 50 082
Inputs/Outputs
Flue gas temperature input:t
tt
Serial interface:t
tt
tt
Current loop (analog) outputs (2):t
Relay outputs (3):t
tt
Relay rating:t
Thermocouple, Type K Chromel/Alumel input tttt
into the Transmitter unit or 4-20 mA temp. input
Isolated RS232 or RS485 communications (Modbus) ttt
for: CO concentration, Status, Signal strength,
Initiate check cycle, Diagnostic data
0, 2, 4 -10, 20mA user configurable for track or hold
Independently configurable as System OK,
Maintenance, or Alarm (High or low)
30 V d.c., 1 A
Electrical
Power supply:t
Power consumption:t
85 - 132, 170 - 264 V a.c. (auto selects), 50 - 60 Hz
200 W
Mechanical Data
Mounting Flange*:t
Dimensions (H x W x D):t
(Transmitter and Receiver)t
Weight:t
tt
combustion
Infrared Gas Cell Correlation Technique with tttt
Automatic Cell Leak Detection (9200 Mk II only)
ASA 3”, 150 lb flange (supplied)
264 x 212 x 475 mm / 10.4 x 8.4 x 18.7 in
Note: ‘D’ includes purge
9.4 kg / 20.7 lb (Receiver unit)
10.1 kg / 22.2 lb (Transmitter unit)
efficiency
monitoring
Series 9000
carbon monoxide monitoring
Options
Air mover assembly for air purge
Air purge blower unit
Transfer/Adaptor Flanges
Flue gas thermocouple with current loop transmitter
Land has a comprehensive range of Combustion and Environmental Monitoring Instrumentation.
Land Instruments International Ltd • Dronfield S18 1DJ • England
Email: land.combustion@ametek.co.uk • www.landinst.com • Tel: +44 (0) 1246 417691 • Fax: +44 (0) 1246 290274
AMETEK Land, Inc. • 150 Freeport Rd • Pittsburgh, PA 15238 • U.S.A.
Email: combsales@ametek.com • www.ametek-land.com • Tel: +1 (412) 828 9040 • Fax: +1 (412) 826 0399
Combustion & Environmental
Monitoring
For a full list of international offices, please visit www.landinst.com
Combustion & Environmental Monitoring
Applies in the UK
Copyright © 1998 - 2011 LAND
An ttt
Applies in the USA
Continuous Product Development may make it necessary to change these details without notice
PDS180/10/11