MEMOLUB HPS 25 bar0 pages
SMART LUBRICATION SYSTEMS
MEMOLUB
MEMOLUB® Systems and accessories
MEMOLUB® HPS
High pressure and
autonomous lubrication
system.
MEMOLUB9 EX
Designed for explosive
atmospheres (In zones 2
and 22).
MEMOLUB* EPS
Powered by an external
energy source of 24 Volts
(4,5 Volts and 12 Volts on
demand).
MEMOLUB® PLCdriven
Totally controlled by the
PLC of the machine.
CARTRIDGES AND
POWERPACKS
Low cost replacement
cartridges and non
welded battery packs
are the only consum-
ables required during the
many years of service of
MEMOLUB®. MEMOL-
UB® can also be used
with cartridges filled with
oil for chain lubrication.
MEMOLUB
FULL CONTROL
• Alarm when default.
• Empty cartridge
indicator.
• Settings from
1 week to 2 years.
SPLITTER MEMO
Dedicated to lubricate
2 points with one
Memolub® System.
Distribution Block*
Up to 8 outlets
* Only with Ditrsibution Blocks
approved by Memolub® Int.
For cost reduction
turn to Memolub
SMART LUBRICATION SYSTEMS
Systems Specifications
Dimensions
Cartridge capacity
Lubricants
Battery pack (HPS/EX)
Max. Pressure
Electronic Controls
On/Off function
Temp, exposition
Min. constant (HPS/EX)
Installation thread
Standard Mega Giga
115x101 147x101 228x101
120 cc 240 cc 480 cc
Oils and greases
up to NLGI 2/3 grade.
4,5V Alkaline
25bar
Quartz timer, microprocessor
Immediate response
-40°C to +50°C
Standard -10°C
Mega -5°C
Giga 0°C
1/4 Inch R
MEMOLUB
Basic Settings
Rings
(Color)
Strokes
Per Day
Daily
Output
in CCs
Months
To Empty
120cc
Months
To Empty
240 cc
RBW 24 15.1 0.25 0.5
RW 12 7.6 0.5 1
RB 4 2.5 1.5 3
R 2 1.3 3 6
BW 1.5 1.0 4 8
W 1 0.6 6 12
B 0.5 0.3 12 24(*)
Note : B = Black ring / W = White ring / R = Red ring
* Only with MEMOLUB® EPS model (External Power Supply)
Remote installation or with distributor block 2 to 8 outlets
Lengths of tubing with multi purpose grease grade N.L.G.I. 2, tubing 0 int.6 mm et fittings M8 minimum :
Viscosity
1000 cSt
3000 cSt
5000 cSt
9000 cSt
15000 cSt
Direct
ok
ok
ok
ok
ok
Remote
8 m
6 m
4 m
2 m
1 m
With 0 int.4 mm, divide all distances by 2.
When fittings <M8 used on lube points, use a grease 0 grade.
With Splitter MEMO With progressif distr. block'
4 m
3 m
2 m
1 m
NA
6 m
5 m
4 m
2 m
1 m
by manufacturer recommended
Months
To Empty
480 cc
1
2
6
12
16
240
Electric characteristics
HPS EPS 4.5 V EPS 24 V EPC PLCd
Power Supply Int. Ext. Ext. Int. Ext.
Voltage 4.5 V DC 4.5 V DC 24 V DC 4.5 V DC 24 V DC
Amperage NA 2 A < 0.5 A NA < 0.5 A
Short Circuit protection ok ok ok ok ok
Polarity Protection NA ok ok NA ok
Stroke Duration 8 sec 8 sec 4 sec 8 sec 4 sec
Min. Time between stroke 1 hour 1 hour 1 hour 1 hour 10 minutes
Max. Wire length NA 5m >10m >10m >10m
Wire Section NA 2x0.5 mm2 2x0.5 mm2 2x0.5 mm2 2x0.5 mm2
oo
o
o
(M
o
MEMOLUB International SA
43, rue Bollinckx
B-1070 Brussels
BELGIUM
Phone: +32 (0)2 559 77 22
Fax: +32 (0)2 522 33 11
Represented by
www.memolub.be
MEMOLUB
SMART LUBRICATION SYSTEMS
®
Up to 8 lube points
Long distance performance
Patented setting system
Unmatched ease of use
Suitable to all industries
High return on investment
"