RVO/U-L1 Flow monitor and indicator for gases0 pages
Flow Monitor Flow Indicator
RVO/U-L1
|2^^2^l/mhJ
<v»n<16°
O |<ioo
/ 6 *\
r bar 1
l^^m 200*
350^^
TO
US
Range of Application
Operating Data
Operation
• Float measuring principle
Application
• Mechanical engineering
• Medicine technology
• Pharma industry
• Chemical industry
• Research and development
• Cooling systems and cooling circuits
Features
• Universal orientation
• High reliability
• High switch accuracy
• Infinitely variable switchpoint adjustment through user
• EX-version to ATEX available
• Scales are burned into the sight glass
• Threaded connection, special threads on request
Installation hints
The operating instruction for RVO/U-L must be observed!
• Download: www.meister-flow.com
Operating pressure max.
Pressure drop
Maximum temperature
Accuracy
Measuring Ranges
10 bar
0,02-0,4 bar
100 °C (optional 160 °C)
±10 % of full scale
Type Switch range Air at 1 bar abs. and 20 °C (1)
[Nl/min] [SCFH] [SCFM]
RVO/U-L10080 22,5 - 80 48,0 - 170,0
RVO/U-L10130 50 - 130 105,0 - 275,0
RVO/U-L10420 130 - 420 4,6 - 14,8
RVO/U-L10625 200 - 625 7,0 - 22,0
(1' The specified data are switch-off points,
other switch ranges on request.
-meisters
strdmungstechnik §>
"