NextPhase?0 pages
NextPhaseTM
Triple Shielded, Low Loss Cable Assemblies
The NextPhase series of high performance interconnect cables are designed for end users who
need exceptional insertion loss performance at a reasonable cost. These low density dielectric
cables are available in a variety of suitable diameters which can be selected based on the end
item loss and frequency requirements. The diameter varieties also enable the design engineer
to accommodate a wide range of design requirements in terms of bend radii, weight and
power performance. Each cable features triple shield construction to eliminate interference
from adjacent signals and these high performance assemblies are available with a wide range
of connectors offering excellent VSWR characteristics.
Electrical Data
Mechanical Data (cont’d)
Maximum Frequency:
912 & 916:
919:
930:
40 GHz
24 GHz
18 GHz
50 Ω nominal
Impedence:
Propagation Velocity:
912:
916:
919:
930:
Time Delay:
912:
916:
919:
930:
75.5%
76.0%
76.5%
77.0%
nominal
nominal
nominal
nominal
0.6
0.9
1.1
1.8
in
in
in
in
(1.524
(2.286
(2.794
(4.572
cm)
cm)
cm)
cm)
Weight with Standard Jacket /Armor:
912:
0.02 lbs/ft (0.030 kg/m)
916:
0.04 lbs/ft (0.060 kg/m)
919:
0.05 lbs/ft (0.074 kg/m)
930:
0.09 lbs/ft (0.134 kg/m)
Operating Temp. Range:
1.35 ns/ft (4.43 ns/m)
1.34 ns/ft (4.40 ns/m)
1.33 ns/ft (4.36 ns/m)
1.32 ns/ft (4.33 ns/m)
Shielding Effectiveness:
-90 dB minimum (cable only)
Dielectric Withstanding Voltage:
912:
5 kV at 60 Hz
916:
7 kV at 60 Hz
919:
10 kV at 60 Hz
930:
15 kV at 60 Hz
Capacitance:
912 & 919:
916:
930:
Static Bend Radius:
912:
916:
919:
930:
26.7 pF/ft (87.6 pF/m)
26.9 pF/ft (88.3 pF/m)
26.2 pF/ft (86.0 pF/m)
-85 to 392º F
(-65 to 200º C)
Above 185º F (85º C) use “T” designation
Cable Construction
Inner Conductor:
Solid Ag-plated Cu
Dielectric:
PTFE Tape
Outer Conductor: Ag-plated Cu Flat Braid/
Polyamide Foil/Ag-plated Round Braid
Standard Finish:
FEP
(a wide variety of other protective finishes
and armors available)
Available Connectors
912: 2.4mm, 2.92mm, 3.5mm, SMA, TNC,
Type N
Mechanical Data
Finished Outer Diameter:
912:
0.126
916:
0.160
919:
0.205
930:
0.305
in
in
in
in
(0.320
(0.406
(0.521
(0.775
cm)
cm)
cm)
cm)
916: 1.85mm, 2.4mm, 2.92mm, 3.5mm,
SMA, TNC, Type N
919: 3.5mm, BNC, SMA, TNC, Type N
930: 7-16 DIN, SMA, TNC, Type N
(maximum frequency dependent on cable;
other connectors available)
Excellence in RF Interconnects
2098 West Main Street, Stroudsburg, PA 18360
Tel: 1-877-MegaPhase / 570-424-8400
Fax: 1-877-MegaFax / 570-424-6031