Gas sampling - Sample tubes 0 pages
M&C | TechGroup Germany GmbH
Rehhecke 79, D-40885 Ratingen
info@mc-techgroup.com
www.mc-techgroup.com
Fon +49 (0)2102 935-0
Fax +49 (0)2102 935-111
2-1.1.0.6 09.96/06.06
Application
The M&C sample tubes are used in combination
with the M&C gas sample probes
series SP® for point selective continuous
gas sampling in processes with low dust
loadings.
Sample Tubes for
Gas Sample Probes Series SP®
with G 3/4"-connection thread
Special Features
For dust loading up to 2g/m3
Point selective sampling
Sampling after wet scrubber up to
90 °C
Sampling temperature up to max.
1800 °C
Different lengths
Great variety of materials
Easy mounting
Description
The M&C probe sample tubes SP210/SS and
SP2000/... are selected according to the specific
applications. Influencing process parameter
are the gas composition, dust content,
water vapure saturation, temperature,
pressure and gas velocity.
Among the standard length “L1” other
lengths up to “L max” are available on
request.
For applications with low sample gas flow,
sample tubes SP2000/SS-Vm are equipped
with volume displacers to decrease the
retention time.
Gas sampling downstream a wet scrubber
with a high content of water carried
out with the M&C sampling tube SP32,
equipped with an integrated demister for
liquid drop collection.
Depending on the selected material, the
M&C sample tubes are equipped with a
welded thread adapter or a support adapter.
They are partly made of different material
than the tubes, depending on fabrication.
See below table.
The connection thread enables an easy
mounting into the mounting flange of the
M&C gas sample probes.
Further sampling accessories:
For a high dust load Pre-filter V20.., V12...
For lower deviation of dew point on process
side heated sample tubes SP30, SP35.
Sample tubes for series SP®