SP210-H/W0 pages
SP210-F
nnnnSpecial Features
nnnn■ Sampling of dust loaded process gases
nnnn■ Small volume, fast response time
nnnn■ Easy mounting and maintenance
nnnn■ Self-regulated electrical heater
nnnn■ Alarm contact for low temperature
nnnn■ Outdoor mounting with protective cover
nnnn■ Insitu probe tube optional
nnnnEmbracing Challenge
nnnnGas Sample Probe Series SP®
nnnnElectrically heated, compact version SP210-H / SP210-H/W
nnnnApplication
nnnnThe M&C gas sample probes version SP210-H
nnnnand SP210-H/W are applicable for continuous
nnnngas sampling.The compact design reguires
nnnnonly limited space.
nnnnThe gas sample probe SP210-H/W is
nnnneguipped with an extra protective cover
nnnnpreferably for outdoor mounting.
nnnnThe maximum operating temperature of the
nnnntube out of stainless steel is 600 °C.
nnnnIn case to avoid cooling and condensation of
nnnnthe sample in the insitu tube from the sample
nnnnpoint to the heated sample probe the SP
nnnn30-H or SP 35-H heated sampling tubes can
nnnnbe used.
nnnnDescription
nnnnThe design of the M&C probes version
nnnnSP210-H and SP210-H/W guarantees simple
nnnnmounting, safe operation and problem-free
nnnnmaintenance.
nnnnChanging the external filter element needs
nnnnno tools and no disassembling of the sample
nnnnline. The complete filter assembly is removed
nnnnout of the probe head. This simplifies the
nnnncheckup of the filter element and the gaskets.
nnnnThe filter area of the probe head respec-
nnnntively the insitu probe tube can be cleaned
nnnnvery easely without dismounting the sample
nnnnprobe. The large external filter element of
nnnnceramic with 2um porosity is heated up with
nnnnthe stainless steel probe head to constant
nnnn180 °C, using a special selfregulated heating
nnnnelement. This avaoids dew point problems at
nnnnthe probe flange and filter area. A heat insula-
nnnntion covers all sides of the probe and ensures
nnnnan optimized heat distribution as well as safe
nnnnoperation.
nnnnThe power supply of the probe can be in
nnnna range between 110V and 240V without
nnnnswitching. No thermostat or temperature lim-
nnnniter are necessary.
nnnnThe separate thermo switch enables a low
nnnntem-perature monitoring (< 160 °C, NO). For
nnnnelectrical connection a junction box with
nnnnterminals is mounted.
nnnnThe gas sample probe SP210-H/W eguipped
nnnnwith a protective cover with guick clamps is
nnnnrecommended for outdoor-mounting.
nnnnThe stainless steel insitu probe tube SP210/
nnnnSS (option) is screwed into the DN65 PN6
nnnnmounting flange.
nnnnTechnical specifications and illustrations are without
nnnnobligation, subjectto modifications. 10.04/06.06
nnnnM&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
nnnnnfo@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-11'
"