KA24 gas-fired combined-cycle power plant0 pages
GAS PRODUCT SOLUTIONS
GT24 / KA24 CCPP
Suited for load balancing energy production
Alstom’s KA24 offers low
part-load CO2 emissions,
unique low-load operation
capability and best
all-round plant efficiency.
The pioneer in fast and flexible
performance
The KA24 Combined-Cycle Power Plant (CCPP) features the superior GT24 gas
turbine offering unrivalled versatility, cost savings, reliability and performance.
The latest GT24 gas turbine is the fourth evolutionary development stage since
its introduction to the 60 Hz market featuring higher base-load and
part-load performance, lower emissions and significantly lower cost of electricity.
With its unique sequential combustion technology, annular combustors and
welded rotor design, the GT24 based KA24 advanced-class CCPP for the 60 Hz market
is particularly suited for load balancing energy production.
Furthermore Alstom’s innovative online switchable operation mode between
Performance Optimised and Maintenance Cost Optimised delivers up to 30%
more operation time between scheduled inspections, resulting in higher availability
and lower maintenance costs.
Customer benefits
OPERATIONAL VERSATILITY
Unique ability to switch online between two
operational modes – Performance Optimised
for higher power output or Maintenance
Cost Optimised for up to 30% more operation
time between scheduled inspections.
HIGH RETURN RATE
Reliable and efficient operation over a wide
operating range with low NOx emissions.
FUEL FLEXIBILITY
Alstom’s robust sequential combustion
design supports a wide range of fuel
variations, including Liquefied Natural
Gas (LNG) and synthetic gases.
LOW-LOAD OPERATION
Low-load operation point of around 11%
combined-cycle load.
TPWR/PRSHT/SLBEP/EN/11.2014/CHE/1709
HIGH OUTPUT and EFFICIENCY
Best all-round plant efficiency of up to
59% and loads up to 680 MW and more
in combined-cycle operation.
START-UP TIME
30 minutes hot start-up capability and a
non-spinning reserve capability that can
deliver 60% base load in just 10 minutes.
© ALSTOM 2014. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be
relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is
provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority,
is strictly prohibited. Photo credits: © ALSTOM 2014. All rights reserved. Printed on environmentally friendly paper.
RELIABILITY
More than 2.5 million fired hours, 57,000
starts across a fleet of more than 50 units
worldwide.
Proven ability to operate in ambient
temperatures as low as -30°C and as high
as 55°C and above.