KA26 gas-fired combined-cycle power plant0 pages
GAS PRODUCT SOLUTIONS
GT26 / KA26 CCPP
Unparalleled performance, maximum return
Alstom’s KA26 offers
ultimate versatility,
performance and emission
reduction for maximum
return in ever changing
market conditions.
The pioneer in operational flexibility
With the KA26 Combined-Cycle Power Plant (CCPP), Alstom is showcasing
its operational flexibility and best plant efficiency across the entire load range
answering customers’ needs wanting versatile solutions. Featuring unique
sequential combustion technology, annular combustors and welded rotor design,
the GT26 based KA26 advanced-class CCPP for the 50 Hz market delivers
high efficiency at conventional firing temperatures achieving lower emissions.
For the first time in an advanced-class engine, the GT26 gas turbine incorporates
an innovative online switchable operation mode between performance optimisation
and maintenance cost optimisation that creates up to 30% longer operation
time between scheduled inspections, resulting in higher availability and lower
maintenance costs.
Customer benefits
OPERATIONAL VERSATILITY
Unique ability to switch online between two
operational modes – Performance Optimised
for higher power output or Maintenance
Cost Optimised for up to 30% more operation
time between scheduled inspections.
FUEL FLEXIBILITY
Alstom’s robust sequential combustion
design supports a wide range of
fuel variations, including Liquefied Natural
Gas (LNG) and synthetic gases.
Superior low-load capability allows parking
at 15% combined-cycle load during
periods of low power demand with all
components fully online.
TPWR/PRSHT/UPMR/EN/11.2014/CHE/1710
HIGH OUTPUT and EFFICIENCY
Best all-round plant efficiency over the entire
load range with more than 500 MW at
60% efficiency and above in combined-cycle
operation.
START-UP TIME
30 minutes hot start-up and a 15 minute
spinning reserve delivering 350 MW
for a KA26-1 configuration and 700 MW
for a KA26-2 configuration.
© ALSTOM 2014. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be
relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is
provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority,
is strictly prohibited. Photo credits: © ALSTOM 2014. All rights reserved. Printed on environmentally friendly paper.
RELIABILITY
2.6 million fired hours, 30,000 starts across
a fleet of more than 85 units worldwide.
Proven ability to operate in ambient
temperatures as low as -30°C and as high
as 55°C and above.