SP100B0 pages
Detailed Literature Available
tCatalogst
Numbert
Liquid Pumps
Air or Gas Driven
LP500
Gas Boosters
Air or Gas Driven
GB500
Includes
Principle of operation, benefits. Applications,
installation detail, chart of rated pressures,
port sizes and weights, performance curves,
standard modifications.
12 Pages
GB500C
AIR DRIVEN
GAS BOOSTERS
NEVIRD RIA
CONTENTS:
•
•
Principle of Operation, Benefits, Features,
Typical Gas Booster Applications
2
•
•
•
Why Use Air Driven Gas Boosters?,
International Equivalents
How Do Buyers Choose Between Gas Booster Models?
Determining the Proper Gas Booster Model—Examples
Gas Booster Selection Table and Notes
•
•
•
•
•
•
How to Use the Performance Curves
Performance Curves
Installation Dimensions, Weights
Standard Modifications
Hydraulics International, Inc. Overview
Other HII Products
3
3, 4
4, 5
6, 7, 8
9
10, 11, 12
13, 14
15
15
16
Principle of operation, benefits. Applications,
typical schematics, selection tables,
performance curves and modifications.
16 Pages
Chatsworth, California, USA
EGB100
The Most Revolutionary
ELECTRIC GAS BOOSTER In Its Class
RATED TO 10,000-PSI (690 BAR)
Series 2G Electric Driven Booster package is
ideal for filling or topping off low-pressure
and high-pressure bottles. Its two-stage
and double acting design uses NO Belts or
Pulleys, making it the quietest Electric
Driven Booster in its class; only 60 dBA. Air
cooled thru its gas barrels inside cooling sleeves
reducing the heat of compression for long seal life.
CONTROLS INCLUDED:
SERIES 2G
SPECIFICATIONS:
Automatic stop control FACTORY
pre-set to any pre-selected
pressure up to 10,000-PSI (690 Bar)
Manual start & stop
Safety relief valve
Inlet/Outlet Pressure Gauges
Outlet Pressure Regulator
Hour Meter, present 6-Digits
■ Sealed Ball Bearings
■ Inlet/Outlet 5-Micron Filters
■ Dual output control (optional)
■ Adjustable pressure switch
DIMENSIONS:
11.5” H x 22” D x 32” W
WEIGHT:
145 Pounds (65.9 Kg)
PORTS (INLET/OUTLET):
37º Flare 1/4”
MAX. OUTLET PRESSURE: 10,000-PSI (690 BAR)
MOTOR:
2-HP @ 1750 RPM
LOW NOISE LEVEL: 60 dBA
VOLTAGES:
115 VAC, 24 Amps, 1-Phase, 60 HZ
220 VAC, 12 Amps, 1-Phase, 60 HZ
230 VAC, 6.8 Amps, 3-Phase, 60 HZ
460 VAC, 3.4 Amps, 3-Phase. 60 HZ
380 VAC, 3.6 Amps, 3-Phase, 50 HZ
OPERATING SPEED: 43 cycles/minute (CPM)
(Optional 69-CPM)
■
■
■
■
■
■
Gas Boosters
Electric Driven
EGB100
Pressure ratings, type of controls, voltages,
flow rate, weight, dimensions and key features
1 Page
AA500
Principle of operation, replacing dedicated air
compressor in large plants, installation,
controls, schematics and packaged systems.
4 Pages
FM-100
Principle of operation, applications, design
features, flow ranges and sizing guides with
calculations. How to order.
58 Pages
MODEL SELECTION TABLE
Minimum Gas Inlet
Pressure-PSI (Bar)
Maximum Pressure PSI (Bar)
MODEL 2G-
Inlet
Outlet
185 (13)
105 (7)
670 (46)
375 (26)
1900 (131)
3380 (233)
3500 (241)
6000 (414)
3500 (241)
6000 (414)
6000 (414)
10,000 (690)
3500 (241)
6000 (414)
TWO STAGE
730
750
1430
1450
3050
5092
DOUBLE ACTING
3030
5050
3500 (241)
6000 (414)
Maximum Flow RateSCFM (NM3/MIN)
Maximum Cycle
Rate (CPM)
30 (2)
30 (2)
60 (4)
60 (4)
200 (14)
300 (21)
2.20 (0.06)
1.20 (0.034)
4.00 (0.11)
2.30 (0.07)
4.80 (0.14)
5.40 (0.15)
69
69
69
69
69
69
200 (14)
200 (14)
16.00 (0.45)
18.00 (0.51)
69
69
HYDRAULICS INTERNATIONAL, INC.
9201 Independence Avenue, Chatsworth, CA 91311 USA
www.hiipumps.com
(818) 407-3400
AA500B
NEVIRD RIA
AMPLIFERS
t
.
r
o
n
.
t
e
e
SINGLE ACTING
AIR PRESSURE
ERUSSERP RIA
AIR DRIVEN
d
DOUBLE ACTING
3A-SS-2.5, 3A-SS-4
5A-DS-2
Hydraulics International air driven air pressure
amplifiers operate using the principle of differential areas.
Like any air tool, they operate from a single shop air
connection for most applications. The air used for cycling
exhausts through the muffler provided, or may be piped
out of the area. The rest of the air is compressed to a
higher pressure output. When output demand stops, the
unit will stall in a force balanced condition consuming no
power nor generating any heat. When output demand
resumes, the unit automatically responds and cycles at
the rate needed to meet that demand, up to the units
capacity.
Output Flow Reaches Maximum as the amplifier’s output
pressure approaches the plant air input pressure. Output
Flow Drops to Zero as the unit reaches theoretical stall. This
value is estimated by multiplying input pressure x the last
digit of the model number, e.g. model 5A-DS-5 with 100
PSI plant air input will stall at approximately 500 PSI, model
5A-DS-2 at approximately 200 PSI. In practice however,
controlling the maximum pressure desired is usually done
with an external control.
FEATURES • BENEFITS • APPLICATIONS
• Compact: installs off the floor, out of the way, in any
position.
• 2 connections: plant air in, amplified air out. (Pilot air
connection is optional for start-stop control with a PCV
valve or solenoid valve and pressure switch).
• Can replace a dedicated air compressor: 10 HP size
in a typical large plant spot requirement for 100 PSI
when only 80 PSI is available. (Model 5A-DS-2)
• Replace bottled nitrogen: up to 700 PSI for air
testing, lab or production. (Model 5A-DS-5)
5A-DS-5
INSTALLATION AND CONTROLS
Although there are a number of options for controlling
these units, a final recommendation will be based on how
the high pressure output air is to be used. Perhaps the most
common type of control is that similar to a conventional air
compressor:
1. Amplify the air into a receiver tank, ASME coded if
permanently mounted.
2. Provide a safety relief valve at maximum rated tank
pressure.
3. Provide a pressure switch* set to stop the air amplifier
unit at about 95% of safety relief valve setting.
4. Provide an air or gas regulator (reducing valve) on the
tank output set at the minimum useable amplified air
pressure for the application.
* The pressure switch need not be electrical. Instead, the
HII series of PCV valves performs this function in one simple
unit with no electrical input required. (Ref. Fig.A, Pg. 3)
TYPICAL APPLICATIONS FOR HIGHER
AIR PRESSURE
Air Amplifiers
Air Driven
• Off road tires
• Valve actuators
• Pneumatic nailers,
staplers, straping
machines
• Air starters
• Bin vibrators
• Pneumatic drill motors
• Air/oil hoists
• Air clamps
• Air presses
• Air brakes
Chatsworth, California, USA
Flowmeters
Liquid or Gas
tBulletinst
Numbert
Includes
Liquid Pumps
Basic pressure ratings, displacement per cycle,
weights, dimensions and key features.
2 Pages
Gas Boosters
PRODUCT LINE
LP501
GB501
Basic pressure ratings, displacement per cycle,
weights, dimensions and key features.
2 Pages
PBVF-100
Quick reference to the overall capacities of HII's
liquid pumps, gas boosters, air pressure amplifiers,
high pressure accessories and flow meters.
4 Pages
PBVF-100B
OVERVIEW
Flow
Meters
Air Driven
Pumps
r
Air Driven
Gas Boosters
.
Packaged
Systems
le,
s.
s
Air Pressure
Amplifiers
Product Line
Overview
High Pressure
Valves
BA
. 2007
Chatsworth, California, USA
High Pressure
Valves
Breathing Air
Scuba Diving
V-100
GB-102
Relief, pilot cutoff, unloading, check, plus gas
receivers and needle valves.
2 Pages
Breathing air booster unit for dive store scuba
tank fill stations to 4500 PSI.
1 Page
9201 Independence Avenue, Chatsworth, CA 91311 USA
© HYDRAULICS INTERNATIONAL, INC. 2010
Tel: (818) 407-3400 • Fax: (818) 407-3428 • Email: sales@hiipumps.com
"