LRS-9424B, Laser Reliability and Burn-In Test System0 pages
reliable
affordable
exible
LRS-9424B Specications
Laser Test Fixtures
System
Why Choose ILX Lightwave?
System Capacity
Device Types Supported
Devices per Fixture
Experience.
For twenty ve years, ILX Lightwave has been a pioneer in
laser diode instrumentation and test systems, starting with the
industry’s rst precision laser diode current source in 1986. Since
then, we have continued to grow and evolve with the expanding
photonic industry, building a tradition of innovation, quality, and
customer service.
Temperature Range
With 25oC Option
Multiple Temp Control
Temperature Accuracy
25oC to 100oC
100oC to 150oC
Maximum T
Between Fixtures
Pin Conguration
Dimensions:
Single Wide (HxWxD) cm
Materials
Maximum Temperature oC
User-Specied
Temperature Control
Quality.
ILX Lightwave has maintained ISO 9000 certication since 2001.
Strong internal systems for problem identication and resolution
have resulted in continuous improvement of our products and
services. We believe that quality is not just something you build
into a product; it’s something you build into everything you do.
Commitment.
ILX Lightwave’s mission is to be the world leader in laser diode
instrumentation and test systems. The company’s Laser Diode
Test Systems group is led by the President to ensure high focus.
After Sales Support.
ILX understands the need for fast, technically accurate responses
to all support requests. In addition to customer service
engineers, our test system customers have direct access to ILX
Lightwave application and design engineers to ensure the highest
level of technical support.
o
o
1024 devices
TO-Can, TOSA, Custom
Up to 32
C
C
o
40 - 150
25 - 100
Yes
System Control Computer and
Supervisory Software
+1.0
+2.0
o
Computer
Dell® Optiplex, > 2.7 GHz
Pentium® Dual Core processor,
2.0 GB ram, 160 GB hard drive,
CD-ROM, Ethernet interface,
Display
Power Requirements,
Computer
C
o
C
17” Dell® Ultrasharp at panel
60
C
Laser Control
Output Polarity
Drive Current
Range
mA
Setpoint Accuracy
mA
Stability1
% of FS
Compliance Voltage
V
Control Modes
~2.5 x 9.5 x 43.5
FR406 and Stainless Steel
170
Bipolar, User Selectable
200
400
+0.1
+0.1
+0.1
+0.1
3.0V Typical, 2.8V minimum
ACC, APC, LIV
115/230VAC, 50/60 Hz,
single phase, 6/3A autosensing
> 5 minutes
Microsoft Windows XP Pro®
Battery Backup
Operating System
System Control Software
Source Code
ReliaTestTM
C# source code provided
with system
General
Measurement Functions
Laser Voltage
Range
V
Accuracy
V
Internal Monitor Photodiode
Reverse Bias Range V
Measurement Range A
Accuracy
A
Stability1
% of FS
Front-Facet Photodetector
Detector Types
Measurement Range
Stability1
Measurement Mode
0-5
+0.01
0-8
0 - 2000
+2
+0.1
Si, InGaAs
User-Specied
+0.1% of Full Scale
Relative or Absolute
Size (HxWxD) cm
Weight
kg
Power Requirements
168 x 92 x 102
365
180 - 264 VAC, 50/60 Hz,
single phase, 30A
Notes
1. Stability measured over 1000 hours
In keeping with our commitment of continuing product improvement, ILX
Lightwave reserves the right to change specications without notice and
without liability for such changes.
www.ilxlightwave.com
800.459.9459
406.556.2481
sales@ilxlightwave.com
31950 E. Frontage Rd.
Bozeman, MT 59715
Rev 03. 092209
LRS-9424B
LASER RELIABILITY AND
BURN-IN TEST SYSTEM