VP Series0 pages
I Small capacity air pump
IVP-4020 / 5030 / 0035
inlet
outlet
'The nozzle position of images are examples.
Dimensions
(unit: mm)
120
Specifications
VP-4020 | VP-5030 | VP-6035 | |||||||
Rated voltage [V] | AC 100, 120, 230 | ||||||||
Power frequency [Hz] | 50 | 60 | 120V 60 | 50 | 60 | 120V 60 | 50 | 60 | 120V 60 |
Max airflow volume [L/min] | 42 | 40 | 43 | 46 | 50 | 54 | 52 | 59 | 60 |
Max power consumption [W] | 16 | 17 | 18 | 23 | 26 | 27 | 30 | 36 | 35 |
Sound level [dBA] | 41 | 42 | 43 | 41.5 | 42 | 44 | 42 | 43.5 | 45 |
Weight [kg] | 1.95 |
'The figure represents the standard configuration. Customization of nozzle position is available.
'Sound data shown is with pump operating at lOkPa and exhaust plumbed
away from the unit.
Performance Curve
VP-4020
VP-5030
■50Hz —60Hz —120V(60Hz)
VP-6035
20
[kPa]
20
[kPa]
* All characteristics values are only for reference, and are not guaranteed values.
* Note that the operating temperature for our pumps is 41°F(5°C) to 104°F(40°Q.
LINEAR AIR PUMPS
I Small capacity air pump
IUP-4020S / 5030S / 6035S
VP-4020,5030,6035 : Pressure
VP-4020S,5030S,6035S : Pressure & vacuum
Flexible body Structure "Customization of nozzle position
Built-in use
*No power plug included because it is designed for built-in use.
'Rubber-made legs are sharp-pointed. Not for self-standing installation
| Applications
• Air mat, Air bed (continuous air exhaust)
• Air bearing
• Air massager
• Scientific & chemical instruments
(analysis and agitation)
Dimensions
Specifications
(unit: mm)
VP-4020S | VP-5030S | VP-6035S | |
Rated voltage [V] | AC 100, 120, 230 | ||
Power frequency [Hz] | 50 i 60 | 60 | 50 i 60 | 60 | 50 i 60 | 60 |
Max airflow volume [L/min] | 47 i 46 i 47 (-47)j(-45)j(-46) | 56 i 59 i 58 (-56)j(-58)j(-57) | 63 i 70 i 66 (-63)j(-69)j(-65) |
Max power consumption [W] | 16 17 18 | 23 26 27 | 30 36 35 |
Sound level [dBA] | 315 34.5 | 35 39 38 | 36.5 40.5 40 |
Weight [kg] | 1.95 |
'The figure represents the standard configuration. Customization of nozzle position is available.
'The value in parentheses represents vacuum.
'Sound data shown is with pump operating at lOkPa and exhaust plumbed
away from the unit.
Performance Curve
Vacuum VP-4020S Pressure
Vacuum VP-5030S Pressure
■50Hz —60Hz —120V(60Hz)
Vacuum VP-6035S Pressure
-40 -30 -20 -10 0 10 20 30 40
[kPa]
-40 -30 -20 -10 0 10 20 30 40
[kPa]
-40 -30 -20 -10 0 10 20 30 40
[kPa]
* All characteristics values are only for reference, and are not guaranteed values.
* Note that the operating temperature for our pumps is 41°F(5°C) to 104°F(40°C).
\b TECHNO TAKAT5UKI CQ..LTD. HlBLQIrV FRANCE s.A.s HlBLQIrV SPAIN s.L
(HIBLOW GROUP HEAD OFFICE) TEL+33-1-61-37-09-15 TEL+34-91-669-3953
"