7110 pages
Cable Glands
711 (& 713)
North American Cable Glands/Connectors
106
Explosion Proof
IECEx and ATEX Approved Flameproof Exd,
Increased Safety Exe and Restricted Breathing ExnR
(Note: Dual Marked UL & ATEX as standard).
'G' Approx (Fully Compressed Length)
Compound Deluge Boot
Ø 'B'
Entry Thread
Ø 'E'
Ø 'D'
A
Application
Entry Thread Size
Size Ref.
A
B
C
C2
D
E
F
H¹
NPT
Standard
or Option
Metric *
½" or ¾"
¾" or 1"
1" or 1¼"
1¼" or 1½"
2" or 1½"
2½" or 2"
3" or 2½"
3½"
M20
M25
M32
M40
M50
M63
M75
M90
• Outdoor or indoor use.
• For use with continuous corrugated aluminium Metal Clad (MCHL) cable.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Cable Acceptance Details
Inner Jacket / Cores
Outer Jacket 'B'
Armour
Max. No. of
Max. Over
Jacket ‘E’
Min.
Max.
Cores
Cores ‘D’
Min. Max.
0.43"
0.41" 0.64"
10
0.49"
0.81"
0.64"
0.49" 0.93"
21
0.66"
1.02"
0.86"
0.85" 1.23"
42
0.87"
1.30"
1.04"
1.17" 1.59"
60
1.10"
1.61"
1.46"
1.37" 1.96"
80
1.42"
2.07"
1.88"
1.76" 2.55"
100
1.81"
2.57"
2.32"
2.29" 2.98"
120
2.24"
3.07"
2.79"
2.93" 3.47"
120
3.07"
3.52"
Hexagon Dimensions
'G'
2.44"
2.68"
2.76"
2.96"
3.18"
3.21"
3.54"
4.33"
Across Flats
Across
Corners
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
4.18"
1.28"
1.56"
1.99"
2.36"
2.79"
3.46"
4.09"
4.84"
All dimensions in inches (except * where dimensions are in millimetres). A - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread.
For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify
when ordering
¹ UL approved only.
Technical Data
• UL Listing No: E84940.
• Suitable for use in:
• Class 1, Division 1, Gas Groups A, B, C and D
• Class 1, Zone 2, Gas Groups IIA, IIB and IIC
• AExd IIC and AExe II Class 1, Zone 2.
• Flameproof Exd, Increased Safety Exe II 2 GD and Restricted
Breathing ExnR II 3G.
• Certificate No’s: Sira 06ATEX1295X and IECEx SIR 06.0082X.
• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas
Groups IIA, IIB and IIC.
• Construction and Test Standards: UL 2225, IEC/EN 60079-0,
•
•
•
•
•
IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0
and IEC/EN 61241-1.
Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to
IEC/EN 60529 and NEMA 4X.
Deluge Protection to DTS01.
Operating Temperature Range: -50°C to +60°C (UL) and -60°C to
+80°C (ATEX / IECEx).
Assembly Instruction Sheet: AI 317 (UL) and AI 338 (ATEX / IECEx).
Alternative certification options available:
DNV Marine Approval
Features
• Provides 360° armour grounding which is fully Inspectable.
• Grounding Device remains in contact with cable when
disassembled for inspection.
• Provides a barrier seal between the individual insulated
•
•
•
•
•
conductors within the cable and prevents entry of the
products of an explosion into the cable.
Assembly of the cable gland compresses and distributes the
compound evenly to effect a barrier seal at the point of entry
into the enclosure.
Provides an outer deluge seal to prevent moisture ingress
to the cable armour and enclosure. Deluge seal is coloured red
to indicate Hazardous Location product.
Provides a cable retention and low smoke and fume, zero
halogen seal onto the cables outer jacket.
Manufactured in Brass (standard), Nickel Plated Brass,
316 Stainless Steel or Aluminium.
Brass NPT entries are nickel plated as standard.
ABS Marine Approval
Ordering Information
Format for ordering is as follows:
Cable Gland / Connector Type
711
Size
C
Thread
1" NPT
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
www.ehawke.com
HPG01