PS2000 pages
Wide range AC/DC Power Supply
PS200-48-32-GR
Single Output switchable to 32V or 48V
• Input can be connected to street lighting
for use at outdoor events
• Output suitable for stepper motors
including moving-head lighting systems
INPUT
Input Voltage:
Frequency:
Inrush Current:
Power Factor:
Efciency:
90 – 277V RMS
47-63Hz
25A max., cold start at 25°C, 120VAC
50A max., cold start at 25°C, 250VAC
0.90 typical at 230VAC, full load
0.95 typical at 115VAC, full load
86% typical at 230VAC, full load
82% typical at 115VAC, full load
Output Voltages, Currents and Regulation Set Point – V1A & V1B
Output
Output Voltage
Minimum Load
Maximum Load
Peak Load
V1A
32V
0
6.2A
7.2A
V1B
48V
0
4.2A
4.5A
Line Regulation:
±0.2% for Input Change from Vin (Min)
to Vin (Max)
Load Regulation: ±0.4% for load change from zero to
full load
Ripple & Noise: 150mVp-p Max. 20Mhz BW
Hold-Up Time:
16msec minimum at full load
Over-current Protection:
YES
Over-voltage Protection:
YES
Over-temperature Protection: YES
Outline Drawing
33,1
ALTERNATIVE MOUNTING HOLES
M3 FLUSH FASTENERS
MAX PENETRATION 8mm
THIRD ANGLE
PROJECTION
117
5
38,1
5W (PIN 2&4 REMOVED) 0.156" VERT HEADER
LEOTRONICS 3966-2051
E
ENVIRONMENTAL SPECIFICATIONS
N L
MEETS FCC CLASS B, CISPR 22 CLASS B,
EN55022 CLASS B. With external line lter.
Safety Agency Compliance:
UL 60950-1; CSA C22.2 -234, LEVEL 3;
EN-60950-1, CLASS 1, SELF CE-MARK
Leakage current: <500µA @50/60 Hz, 264VAC input
300,000 hours minimum per BELCOR 332,
MTBF:
issue 6 specication at 30°C.
(Max. junction temperature 110°C,
Capacitors 105°C)
Size:
127 x 84 x 38mm (3.3 x 5.0 x 1.5")
Weight:
700gr. max. (26oz)
CON3
CON2
83,82
32 / 48V
JUMPER FITTED FOR 32V
127
117
ALTERNATIVE MOUNTING HOLES
M3 FLUSH FASTENERS.
MAX PENETRATION 8mm
33,1
5
8,26
109,22
MOUNTING HOLES
M3 FLUSH FASTENERS
MAX PENETRATION 5.5mm
13,34
SAFETY REGULATORY & EMC SPECIFICATIONS
0V
57,15
Operating Temperature:
-40°C (will switch on) to +50°C
(de-rating linearly to 70°C at 2.5%/C)
Temperature Coefcient:
0 to 70°C ± 0.02%/°C
Cooling:
100W free convection cooling (base plate
cooling)
200W (forced air cooling – 250 LFM)
Humidity:
5% to 95% RH non-condensing
All specications are subject to change without notice.
DRAFT
Tel: +44 (0) 1722 413060
Fax: +44 (0) 1722 413034
6W 0.156" VERT HEADER
LEOTRONICS 3966-2061
CON1
sales@greshampower.com
www.greshampower.com