Contilog - Temperature and Gas Pressure Measurement with Wireless Sensor Technology during Hot Pressing0 pages
Technical Specifications
Data Logger
■■ Dimensions (L x W x H)............79 x 67 x 5.5 mm
■■ Weight............................................ approx. 22 g
■■ Power supply............................3.0 V / 560 mAh
■■ Interval between two measurements............0.5 s
Gas Pressure Sensor
■■ Absolute measuring range.............. 0 to 600 kPa
(above atmospheric pressure)
■■ Max. measuring inaccuracy....................... 2.5 %
(at 0 to 85 °C)
Fagus-GreCon
Greten GmbH & Co. KG
P.O. Box 1243
D-31042 Alfeld-Hanover
Phone
Fax
E-Mail
+49(0)5181-79-0
+49(0)5181-79-229
sales@grecon.com
www.grecon.com
Temperature and Gas
Pressure Measurement with
Wireless Sensor Technology
during Hot Pressing
Digital Temperature Sensor
■■ Measuring range........................... up to +125 °C
■■ Measuring accuracy................................+/-2 °C
■■ Panel thickness................................min. 18 mm
■■ Radio frequency................................... 868 MHz
Reader
■■ Dimensions (excl. edge protector)
................................ approx. 275 x 204 x 27 mm
■■ Weight..........................................approx. 1.1 kg
■■ Display.................................. 10.1” (1366 x 768)
■■ Working memory........................................ 2 GB
■■ Hard disk.................................................. 32 GB
References
■■ Particleboard, OSB, MDF manufacturers
■■ Insulating material manufacturers (up to 125 °C)
■■ Original equipment manufacturers (OEM)
■■ Glue producers
■■ Research institutes
Fire
Protection
Measuring
Technology
Service
EN | R.02 | 2015.04
Subject to technical and country-specific modifications.
© Fagus-GreCon Greten GmbH & Co. KG
CONTILOG
"