Benchtop Conductivity meters HD 2206.20 pages
HD 2206.2
•t Conductivity, dissolved oxygen and temperature probes fitted with SICRAM module can
store factory and calibration data inside.
The instruments HD2206.2 is a datalogger, it can memorize up to 2,000 samples of data.
The data can be transferred from the instrument connected to a PC via the multi-standard
RS232C serial port and USB 2.0. The storing parameters can be configured using the menu.
The RS232C serial port can be used to transfer the acquired measurements to a 24 column
portable printer in real time (HD40.1 or HD40.2).
The instruments equipped with HD22BT (Bluetooth) option can transfer data without any connection to a PC or printer fitted with Bluetooth input or through Bluetooth/RS232C converter.
The software DeltaLog11 allows instrument management and configuration, and data processing on PC.
The instruments have IP66 protection degree.
Technical characteristics HD2206.2
χ - Ω - TDS - NaCl - °C -°F measurement
Instrument
Dimensions (Length x Width x Height)t
Weightt
Materialst
Displayt
t
Operating conditions
Working temperaturet
Storage temperaturet
Working relative humidityt
Protection degreet
-5 … 50°C
-25 … 65°C
0 … 90% R.H. without condensate
IP66
Power
t
t
Auxiliary sockett
t
Mains adapter (cod. SWD10)
12Vdc/1A
For supplying of electrode holder with built-in
stirrer HD22.2
Security of memorized data
t
Unlimited
Time
Date and hourt
Accuracyt
HD 2206.2
BENCH-TOP CONDUCTIVITY METER
265x185x70mm
490g
ABS, rubber
Back lighted, matrix point display.
240x64 points, visible area: 128x35mm
Real time schedule with backup battery 3.6V - ½AA
1min/month max drift
Measured values storing
Quantityt
Storage intervalt
2000 screens
1s … 999s
The HD2206.2 is a bench top instrument for electrochemical measures: conductivity, and
temperature. It is fitted with a large backlighted LCD display.
The HD2206.2 measures conductivity, resistivity in liquids, total disssolved solids (TDS),
and salinity with combined 4-ring and 2-ring conductivity/temperature probes. The conductivity probes can have a direct input or with SICRAM module. The inputs are separate.
Al models are fitted with input for the measurement of temperature with Pt100 or Pt1000
immersion, penetration or contact probes. The temperature probes are equipped with an automatic recognition module and factory calibration data are stored inside.
Vdc in
RS 232
•t The conductivity probe calibration can be performed automatically with automatically
detected conductivity calibration solutions: 147µS/cm, 1413µS/cm, 12880µS/cm or
111800µS/cm or manually with calibration solutions having different values.
7
USB
5
3
1
8
Vdc out
384 Water Analysis
N.c.
8-pole DIN 45326 8
6
4
2
8-pole DIN 45326 8
N.c.
"