SG-BWS English Datasheet0 pages
SG-BWS SERIES
The SG-BWS series presents two models:
• SG-BWS-T4: control unit with plastic
housing for DIN/OMEGA rail mounting
equipped with 16 clamps that can
connect from 1 to 4 photocell couples
of the S5-ST, SL5-ST, S300 series
with OSSD safety outputs;
• SG-BWS-T4-MT: control unit with plastic
housing for DIN/OMEGA rail mounting
equipped with 48 clamps that can
connect from 1 to 4 photocell couples
of the S5-ST, SL5-ST, S300 series and
contemporaneously up to 2 safety light
curtains equipped with safety outputs
activated with two 230V relay.
The SG-BWS-T4 model is WITHOUT
MUTING FUNCTION but presents EDM
and selectable MANUAL/AUTOMATIC
RESTART. The SG-BWS-T4-MT model
is provided with DOUBLE MUTING
FUNCTION. The control unit fits some
safety outputs controlled depending
on the status of the safety photocells
connected to the device. A danger
condition detected by a photocell or light
curtain opens the outputs.
APPLICATIONS
www.automation.datalogic.com
sensor S
Extreme reliability and simplicity make
the SG-BWS control units the ideal
solution for the following applications:
• Automatic warehouses
• Machines for food packaging
• Robots
• Automatic assembling lines
• Machines for PCB production
CSONTAROL UFNITSETY
highlight S
• Two models:
- SG-BWS-T4 WITHOUT MUTING
FUNCTION
- SG-BWS-T4-MT WITH DOUBLE
MUTING FUNCTION
• Factory automation standard housing
with compact dimensions
• Possibility to connect 4 safety singlebeam
and 2 safety light curtains
• PLUS functions: Single/Double muting,
Edged/triggered Override, Double
Muting Lamp, External Muting Enable
• Configurable device through dip-switches
• Satisfies the requirements of key
safety Standards, such as Category 4
of EN 954-1, SIL3 of IEC 61508, and
performance levels PL e of EN ISO
13849-1.