Model-2000 pages
Heated Methane / NonMethane /
Total Hydrocarbon Analyzer (NMHC)
Model-200
The VIG Industries, Inc. Model-200 is a microprocessor based, oven heated methane / nonmethane
/ total hydrocarbon gas analyzer designed for high accuracy, sensitivity and stability. The
Model-200 uses two independent flame ionization detectors (FIDs), one to measure total
hydrocarbons and the second coupled with a GC Column for the separation of the methane and
nonmethane components. A sample is fed to the analyzer via an internal heated pump to the first
FID for a real time total hydrocarbon reading. A portion of the sample is trapped and pushed
through a column to separate the methane component and then to the second FID. Any
remaining sample in the column is back flushed through the column to obtain the nonmethane
component. All components that come in contact with the sample through analysis are
maintained in a temperature-controlled oven to prevent condensation, and to provide repeatable,
reliable performance in the analysis of a wide variety of hydrocarbon concentrations in gaseous
mixtures or in ambient air.
Applications
Features
• Easy to use software
• Automatic start-up/ignition
• Heated sample pump heads
• Two stage sample filter with exchangeable
sintered stainless steel elements
• PTFE isolated detectors (FIDs)
• Automatic fuel shut-o system
• Automatic flame-out indicators
• Adjustable alarm and oven settings
• Precision 1% of full scale
Options
• 4-20mA output - no extra charge
• Zero and calibration solenoids with
software
• RS-232 interface
• Internal combustion air supply
Related Available Equipment
•
•
•
•
•
Zero air generator (Reduces bottles)
Hydrogen generator (Reduces bottles)
Heated sample lines and controllers
Strip chart recorders and data loggers
NEMA rated enclosures
• Compliance Monitoring - U.S. E.P.A.
Method 18 and Method 25A
• Process Monitoring - Continuous monitoring
and alarm or control of: process gas streams
utilizing organic solvents, crude oil, and other
chemicals containing hydrocarbons.
• Efficiency Monitoring - Monitoring euent of
volatile organic compound (VOC) reduction
equipment for environmental compliance,
eciency control of incinerators (Thermal or
catalytic), scrubbers, carbon absorbers, and
other abatement equipment, monitoring of
catalytic converters, combustion and diesel
engine eciency.
• Safety Monitoring - Lower explosive limit
(LEL) monitoring and/or control of
ovens/dryers, fugitive emissions monitoring,
personnel work area monitoring, leak
detection of process equipment or solvent
storage areas.
• Stack Monitoring
VIG INDUSTRIES, INC.
4051 E. La Palma #C Anaheim, CA 92807
• Toll Free (800)862-7844 • Phone (714)632-8200 • Fax (714)632-8201 • http://www.vigindustries.com
"