LRS-03 Sound level limiter-recorder0 pages
LRS-03
Logger-Limiter Sound Level
Main Characteristics
The logger-limiter LRS-03 measures records and limits the sound pressure level
at the site where it is installed. The LRS-03 is inserted into the reproduction
chain, between the mixing desk and the crossover, intervening in the entire
• Frequency-Filter Sound Pres- sound chain.
sure Level limiter based on the The LRS-03 corrects the signal that feeds the amplifier so that the sound presmeasurement of SPL
sure level measured by the sensor does not exceed the programmed maximum
level. The LRS-03 automatically corrects excesses of the sound signal level up
• Control by emission Sound to 40 dB. If this 40 dB is exceeded, then the LRS-03 penalises with an attenuaPressure Level
tion of 60 dB during a programmable period of time.
• 40 dB correction
(attenuation)
range The LRS-03 is also equipped with a recording function that allows the user to
• Registers acoustical parameters like LAeq, LAeq1’max,
LAeq1’min, LFmax, LSmax
and percentiles (interval and
sessions)
store information concerning sound levels measured in the establishment and
concerning incidents that occur, (tampering with the equipment), during a minimum period of one month. The LRS-03 allows you to programme the periodicity
of information storage (from 2 min. to 1 h. in 1-min. steps). The information for
each session is also stored, allowing you to demonstrate the sound levels generated by your activity to the authorities. The information stored can be consulted in various ways: displaying it on the LCD screen or printing it by connecting a parallel printer to the corresponding LRS-03’s output port. The information
can also be transferred to a PC via a USB port or modem.
• Registers all incidents, e.g.
disconnection from the mains
or sensor tampering
The LRS-03 allows the programming of different schedules for daytime and for
night-time evaluation and the maximum levels allowed for each schedule. The
LRS-03 also allows you to enter different working schedules, (session sched• Adaptable to any kind of regu- ules), for each day of the week and can fit any kind of establishment.
lation
The LRS-03 has an internal battery that allows it to keep on working when the
power is disconnected. When the LRS-03 works with the battery, it attenuates
• Internal Battery
60 dB. The battery lasts two days. Before the battery runs flat, the LRS-03 re• Data retrieval by LCD screen, cords the date and time when this happens. It keeps a database with the last 10
printer, serial connection with times the battery has gone flat. When the battery is flat, the LRS-03 continues
USB and modem
attenuating 60 dB until the LRS-03 is connected again to the mains. All the in• Massive data storage for peri- formation is kept in the memory and is not lost. Once the LRS-03 is connected
again to the mains it continues running normally.
• Can be completely sealed
ods longer than 1 month
D_LRS03_v0013_20120614_ENG
An illuminated external display can be connected to the LRS-03. This allows
you to consult the sound pressure level measured and the attenuation applied
by the LRS-03 in real time from another point in the room.