fittings0 pages
IMPACT RING TYPE FITTINGS
Fluoropolymer Fitting FIT-ONE
Designed with simplicity and easy of installation,
FIT-ONE overcomes the shortcoming which flare type fittings have in
common : lacking resistivity
The development of such revolutionary fitting is made possible by our
business model, introducing the following features :
^High resistivity against pulling^
makes a reliable fitting
FIT-ONE Impact-Ring design is a
perfect solution to the shortcoming
of general flare type fitting.
SPECIFICATIONS
Maximum Operating Temperature: 392°F
(Varies upon the Material of Impact-Ring)
Maximum Operating Pressure:101.5 Psi G
Applicable Fluid: Liquid
Applicable Tube Material; PFA or PTFE
Material: NUT: PFA
Body: PFA or PTFE
Small fluid pressure loss and easy replacement
of liquids
Low torque fastening nut helps securing the
flow of fluid path,minimizing the loss of fluid
pressure while decreasaing
liquid remnants.
As a result,
the replacement of liquids
can be carried out easily.
Click-Gauge as the fastening reminder
The Click-Gauge indicates the optimal fastening
location, maximizing the performance of the
fitting without damageing it.
Click Gauge
When the nut is fastened to the optimal
location of the body, the gauge will
notify the operator either through
vibration or sound
The Impact-Ring firmly grips the tube,
achieving high resistivity against pull.
The screw nut will pressure the Impact-Ring
when fastened to the designated location,
securing the conjunction between the tube and the body,
riu
116
101.5
B7
72.5
58
43.5
29
14.5
0
* Patent Pending
'*» | ||||||||||
68 10 | 4 14 | 0 17 | 6 212 248 28 | 4 | 320 356 392 |
•Impact Ring Material PPS
Liquid Temperature °F
Assembly Method
Components and assembly tools
1. IMPACT RING
2. NUT
3. BODY
4. TUBE
5. HOT AIR GUN
6. FLARE TOOLS
NUT
TUBE
IMPACT RING i-v^
First insert a tube into the nut, then insert the Impact Ring.
Hot Air Gun
-High Temperature Hot Air
Tube
!!! Require uniform heating!!!
Insert the tube into flare tool ASAP,
and wait until tube is cooled down.
BODY
Insert flared PFA tube into the fitting body, then tighten the
' y' nut until the bottom paws of which contacts nut head and
click-Gauge.
(Notice : be careful of excessive )
P1
"