Digital DC Drives Comparison Guide.0 pages
HA102624 Issue.n
Page No: 1 of 5
Making It Easier To Control DC Motors
DC Digital Drive Feature comparison guide
This guide will show you the features of the PL/PLX range of DC drives when compared to its immediate competition. It is by no means an exhaustive comparison. Please email your feedback to info@sprint-electric.com. Thanks.
KEY: ƒ¤= yes ƒ¦= no ƒ´= reduced specification £= extra cost option Sprint PL/PLX Parker SSD 590 + CT Mentor2 Lenze 48/4900 ABB DCS500
Unique electronic regenerative stopping facility on most 2Q models.
ƒ¤
ƒ¦
ƒ¦
ƒ¦
ƒ¦
English language display for programmable connection points.
ƒ¤
ƒ¦
ƒ¦
ƒ´
ƒ¦
Digital I/Ps and O/Ps are short circuit proof.
ƒ¤
ƒ¦
ƒ¦
ƒ¦
ƒ´
Digital I/Ps and O/Ps are over-voltage protected.
ƒ¤
ƒ¦
ƒ¤
ƒ¦
ƒ¦
Main & Auxiliary power ports for quick current release at start.
ƒ¤
ƒ¦
ƒ¦
ƒ¤
ƒ¦
4 ergonomically designed keys for Up, Down, Left and Right for easy menu navigation.
ƒ¤
ƒ¦
ƒ¦
ƒ¦
ƒ¦
Motor drive alarms latched for display after power on / off, i.e. message not lost when power turned off.
ƒ¤
ƒ¦
ƒ´
ƒ¦
ƒ¦
Unique „configuration checker detects shorting of user programmed block diagram outputs.
ƒ¤
ƒ¦
ƒ¦
ƒ¦
ƒ¦
All analogue I/Ps have a programmable voltage range up to +/- 30V with up to 5mv resolution with excellent response time.
ƒ¤
ƒ¦
ƒ´
ƒ´
ƒ´
All analogue I/Ps are over-voltage protected.
ƒ¤
ƒ¦
ƒ¤
ƒ¦
ƒ¦
Ability to select 2 sets of motor parameters.
ƒ¤
ƒ¦
£
ƒ¦
ƒ¤
Windows based on/off line graphical configuration & diagnostic tool (supplied FOC inc. connection lead)
ƒ¤
ƒ¦
ƒ´
ƒ¦
£
Friendly easy to use menu structure with English language parameter names.
ƒ¤
ƒ´
ƒ¦
ƒ¦
ƒ¦
Extensive programmable I/O.
ƒ¤
ƒ´
£
£
£
Significant panel space savings due to compact design.
ƒ¤
ƒ´
ƒ´
ƒ¦
ƒ¦
In depth diagnostic functionality available from on board display (in-built meter).
ƒ¤
ƒ´
ƒ´
ƒ´
ƒ¤
Built in oscilloscope output looking at ALL display parameters.
ƒ¤
ƒ´
ƒ¦
ƒ¦
£