High Voltage Vacuum Circuit Breaker0 pages
nf ZN63A(VS1)-12
_ I High Voltage Vacuum
U Circuit Breaker
Profile
The indoor high voltage vacuum circuit breaker
ZN63A(VS1)-12 is used as the indoor switch gear
in 12kV power system. It works as a protective and
controlling unit for the grid equipment and power
equipment in industrial enterprises, with the
advantages of high reliability and long life-span. It
is specially suitable for the frequent operation at
rated current or repetitiously open & close the
shorted circuit. It's widely used in the industries of
power,energy, petrochemicals, metallurgy,
manufacture, transportation, construction,
environment and so on.
The circuit breaker integrates the actuating
mechanism and the breaker into one body, which
may work as a fixed unit or a withdrawable unit
with the special movable structure. The according
interlock can be added to the fixed type breaker to
match the XCN2, GC1A cabinet.
Environment condition:
► The ambient temperature:Not higher than+40°C
or lower than -1 5°C.
» The ambient humidity:
The average daily relative humidity:=95%.
The average monthly relative humidity:=90%.
The average daily vapour pressure:=2.2 X10
Mpa.
The average daily vapour pressure:=l .8X10
Mpa.
» Altitude: Not higher than 1000m.
t Earthquake intensity: Not higher than 8 degree
► No water dripping, No inflammables, explosives,
corrosive gas or strenuous vibration.
27
ZN63A(VS1 )-l 2 Main Technical Parameter
Main technical parameter
No. | Item | Unit | Parameter | |||
1 1 | IxalcU VUllayc | kV | 12 | |||
i. | IxalcU bnUll LIllie pUWcl licLfUcnLy WIlllbLailU VUlLdyc^l ininy | 42 | ||||
3 | IxalcU liyilLIIIIiy IlllUUIac WllllaldllU VUllayc ^pcaK VaiUC) | 75 | ||||
A *t | DaitoH franuant~\i IxalcU llcilUcflLy | nz | 50 | |||
C D | Rated current | A | 630 | 630 1250 | 1250 1600 | 1600 2000 |
1250 | 1600 2000 | 2000 2500 | 2500 3150 | |||
2500 3150 | 3150 4000* | 4000* | ||||
c 0 | —-- Rated current | kA | 25 | 31.5 | 40 | 50 |
7 1 | Rated short time withstand current | 25 | 31.5 | 40 | 50 | |
Q O | ixaicu snuri -LIILUIL pcriuu | 4 | ||||
y | ixaicu pcaK wiiniianu Lurieru | kA | 63 80 100 125 | |||
1 u | Rated Short circuit close current | 63 80 100 125 | ||||
1 1 1 1 | Carnnnar\/ r i ff~11it" nnu/Qr fram ianr\f \AIitrieta nr\ f" ^no/1 rvi i nl jcLuiiuaiy LIILUIL puwci ircu,ucriLy wiLiibLdiiu vuiiaycv 1 fillip | V | 2000 | |||
1 c. | IxalcU olliyic/ UaLK IU UdlK LapaLHUi Scl Upcil LIILUIL LUIICML | A A | C3A//IAA IA f\\r A - QAA IA AA\ 03U/4UU (4UKA.OUU/4UU) | |||
1 J | Ratorl ranaritnr cot rlnco ciirna l\alCU LapaLHUi SCL LIU3C sUiyc | kA | i C.J \ rrcLjucriLy nuL niyncr indn i uuunz j | |||
1 A | LJpcillliy llillc V'dLcU VUllayc/ | ms | 20-50 | |||
1 D | L-iusiiiy LIIIIC v'dicu vuiiayc/ | 35-70 | ||||
16 | Mechanical life | Time | 20000 (50kA: 10000) | |||
1 / | D a tori /~ 11 rront Kra abinn ti tm ocioloftrifal 1 ito ■ IxalcU LUITcni DlcaKiny llinca^ClCLLriLal IlleJ | 20000 (50kA: 10000) | ||||
18 | Rated Rated short-circuit current breaking times | 50 (40kA:30, 50kA:20) | ||||
19 | Contacts allow wear accumulative total thickness | mm | 3 | |||
IxalcU LIUaliiy VUllayc | V | AC110/220 DC110/220 | ||||
21 | Rated opening voltage | |||||
22 | Ratpri vnltanp o.f pnprnv—stnrinn mntnr | |||||
23 | Rated power of energy-storing motor | W | 80 | |||
24 | Time of energy-storing | S | «15 | |||
25 | Clearance between open contacts | mm | 11 ±1 | |||
26 | Over travel | 3.5 ± 1 | ||||
27 | Contacts bounce off time | ms | ==2 | |||
28 | Time difference of three phase opening and closing | =£2 | ||||
29 | Average open time (contacts open 6mm) | m/s | 0.9-1.2 | |||
30 | Average close time (contacts close 6mm) | 0.5-0.8 | ||||
31 | Rated current | mm | =s3 | |||
32 | Resistance of main circuit | uO | s=50(630A) =s45(1250A) «35(1600~2000A) «25(2500 above) | |||
33 | Touch pressure of contacts closed | N | 2400±200 (25kA) 3100±200 ( 31.5kA) 4250±250 (40kA) 7000±250 ( 50kA) | |||
34 | Rated operation sequence | Open-0.3s-opening/closing-l 80s-opening/closing | ||||
Open-180s-opening/closing-l 80s-opening/closing (50kA) |
'Forced air cooling is necessary for upto 4000A device